•  This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L 

nitrite in combination measured as N and is certified for nitrate/nitrite reduction only for water supplies with a 

pressure of 2.8 kgf/cm

2

 (40 psi) or greater.

•  A nitrate/nitrite sampling kit should be used to monitor the nitrate/nitrite levels in your product drinking water 

at least every six months.  Kits maybe purchased from your local dealer or Coway.

•  This system has been tested for the treatment of water containing pentavalent arsenic (also know as As(V), 

As(+5), or arsenate) at concentrations of 0.050 mg/L or less.  This system reduces pentavalent arsenic, but 

may not remove other forms of arsenic.  This system is to be used on water supplies containing a detectable 

free chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only 

pentavalent arsenic.  Treatment with chloramines (combined chlorine) is not sufficient to ensure complete 

conversion of trivalent arsenic to pentavalent arsenic.  Please see the Arsenic Facts section of this Performance 

Data Sheet for further information.

•  Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse 

osmosis treated water under operating conditions that approximate typical daily usage.

•  The product water should be tested every 6 months to ensure that the contaminants are being reduced 

effectively. Please contact your local dealer or Coway to initiate this service.

•  This reverse osmosis system contains a replaceable treatment components, critical for the effective reduction of 

total dissolved solids and that product water shall be tested periodically to verify that the system is performing 

properly. Replacement of reverse osmosis component should be with one of identical specifications, as defined 

by the manufacturer, to assure the same efficiency and contaminant reduction performance.

•  The estimated replacement time of filter, which is a consumable part, is not an indication of quality guarantee 

period, but it means the ideal time of filter replacement. Accordingly, the estimated time of filter replacement 

may be shortened in case it is used in an area of poor water quality.

Model of Filter

Type

Usable period (months)

COST US $

WNF8-S

NEO-SENSE FILTER

6

46.00

WJMF8-20-S

RO MEMBRANE FILTER

20

94.00

WJIF8 –S

INNO SENSE FILTER

18

47.00

WJCC-02

CERAMIC FILTER

12

11.00

ARSENiC FACTS

Arsenic (abbreviated As) is found naturally in some well water. Arsenic in water has no color, taste or odor. It must 

be measured by a lab test. Public water utilities must have their water tested for arsenic. You can get the results 

from your water utility. If you have your own well, you can have the water tested. The local health department 

or the state environmental health agency can provide a list of certified labs. The cost is typically $15 to $30. 

Information about arsenic in water can be found on the Internet at the US Environmental Protection Agency 

website:

www.epa.gov/safewater/arsenic.html

There are two forms of arsenic: pentavalent arsenic (also called As(V), As(+5), and arsenate) and trivalent arsenic 

(also called As(III), As(+3), and arsenite). In well water, arsenic may be pentavalent, trivalent, or a combination of 

both. Special sampling procedures are needed for a lab to determine what type and how much of each type of 

arsenic is in the water. Check with the labs in your area to see if they can provide this type of service. 

Reverse osmosis (RO) water treatment systems do not remove trivalent arsenic from water very well. RO systems 

are very effective at removing pentavalent arsenic. A free chlorine residual will rapidly convert trivalent arsenic 

to pentavalent arsenic. Other water treatment chemicals such as ozone and potassium permanganate will also 

change trivalent arsenic to pentavalent arsenic. A combined chlorine residual (also called chloramine) may not 

convert all the trivalent arsenic. If you get your water from a public water utility, contact the utility to find out if free 

chlorine or combined chlorine is used in the water system.

The P-07CL system is designed to remove pentavalent arsenic. It will not convert trivalent arsenic to pentavalent 

arsenic. The system was tested in a lab. Under those conditions, the system reduced 0.050 mg/L pentavalent 

arsenic to 0.010 mg/L (ppm) (the USEPA standard for drinking water) or less. The performance of the system may be 

different at your installation. Have the treated water tested for arsenic to check if the system is working properly.

The RO component of the P-07CL system must be replaced every 24 months to ensure the system will continue to 

remove pentavalent arsenic. The component identification and locations where you can purchase the component 

are listed in the installation/operation manual.

22

O

thers

PERFORM

ANCE D

AT

A SHEE

| P

-07C

l

Содержание P-07CL

Страница 1: ...P 07CL Water Filtration Device For your safety and proper use of the product please read this User s Manual before use Warranty card is included in this User s Manual...

Страница 2: ...main water with an uniformed water pressure 3 Closed tank for preventing the secondary pollution It is the hygienic by applying the extra closed structure to the inner tank to preventing the secondary...

Страница 3: ...sheet for individual contaminants and reduction performance This system is acceptable for treatment for influent concentrations of no more than 27 mg L nitrate and 3 mg L nitrite in combination measur...

Страница 4: ...mage to the unit may result The filtration device installation shall comply with applicable state and local regulations Operation safety When the water is coming inside of the product or there is a pu...

Страница 5: ...enzene and thinner Otherwise electric shock or fire may occur as a result Do not repair disassemble or modify Otherwise electric shock or product damage may occur as a result Do not use filtered water...

Страница 6: ...Parts name Front Rear Top Cover Inlet Orange Outlet Blue Extraction Lever Room water Extraction Faucet Front Cover 5...

Страница 7: ...smell induction material and to improve taste of water It also has the function to reduce aesthetic chlorine volatile organic compounds VOC s Step 5 CERAMIC FILTER The filter is the core technology o...

Страница 8: ...n tape on the adaptor and fit it to the pipe 3 Connect the faucet with the adaptor 4 Connect 1 4 inch orange tubing with the connector on the adaptor 5 Open the feed valve to supply water to the filtr...

Страница 9: ...long time or you didn t use drain the water inside of the water filtration device completely and remove the newly filtered water one time to use Regular filter replacement It is important to replace t...

Страница 10: ...How to use To drink the room water If you pull the extraction lever downward you can drink the filtered water To extract continuously Please fix the lever by letting extraction lever down about 90 9...

Страница 11: ...Connect the orange color inlet tubing 1 to the tap water supplying pipe Connect the outlet tubing 2 Outlet tubing Blue Inlet tubing Orange 2 1 Main water supply valve 10 Maintenance HOW TO USE To drin...

Страница 12: ...r two times after the product installation Cold water plumbing Please connect the source water Make sure that the source water is not from hot water line If you use hot water as source water then it w...

Страница 13: ...se empty the water tank completely using the continuous extraction method See P 9 3 Please remove the top cover and then un hook the fixed clip holding the top cover of the water tank Now open the tan...

Страница 14: ...shaking and cleansing in the drained water 5 Please wipe the surface of the storage tank with soft clothes 6 Use the storage tank after cleaning it with the drained water and empty the water tank usi...

Страница 15: ...other foreign particles can be entered When you clean the storage tank don t use any chemicals or detergent If you don t clean chemicals or detergent cleanly it can be harmful to the body Keep the sur...

Страница 16: ...e water quality can shorten the filter replacement period The period for the filter exchange is made based on 10 L use in a day for house use 4 people based use for business P 07CL Part No Names of Fi...

Страница 17: ...tion device See P 12 2 Separate the top cover and the front cover Remove the 2 fixing screws at the top of the product and then separate the front cover Don t pull the Cup touch Lever with the excess...

Страница 18: ...that a corresponding filter and a hose are firmly connected and that there is no leakage It is recommended to empty the water tank filled with the filtered water at least one time right after the filt...

Страница 19: ...r replacement Didn t you close the main water supply valve Open the main water supply valve Didn t the temperature of the main water drop suddenly If the water temperature is lowered the water amount...

Страница 20: ...eight 4 5 kg The water amount can be differentiated according to the water pressure and the water temperature The water tank capacity is the amount by the size and can be different from the extraction...

Страница 21: ...WATER FLOW DIAGRAM P 07CL Inno sense Filter 3FHVMBUPS 20 Others SPECIFICATION WATER TER FLOW DIAGRAM...

Страница 22: ...29 6 4 8 78 5 83 7 Selenium 0 05 0 117 0 003 96 0 97 8 TDS 187 5 741 5 57 8 91 5 92 2 Aesthetic Chlorine 50 2 07 0 56 54 53 72 8 VOC 95 reduction 0 32 0 0077 95 70 97 6 While testing was performed un...

Страница 23: ...OST US WNF8 S NEO SENSE FILTER 6 46 00 WJMF8 20 S RO MEMBRANE FILTER 20 94 00 WJIF8 S INNO SENSE FILTER 18 47 00 WJCC 02 CERAMIC FILTER 12 11 00 ARSENIC FACTS Arsenic abbreviated As is found naturally...

Страница 24: ...00023 lindane 0 0002 0 055 99 0 000013 methoxychlor 0 04 0 050 99 0 00013 pentachlorophenol 0 001 0 096 99 0 0013 simazine 0 004 0 120 97 0 0043 styrene 0 1 0 150 99 0 00053 1 1 2 2 tetrachloroethane...

Страница 25: ...MEMO 24 Others PERFORMANCE DATA SHEET P 07CL...

Страница 26: ...bligations other than those specifically identified in the preceding section COWAY is not responsible or liable for personal injury or property damage of any kind even if arising from a breach of this...

Страница 27: ...e Product covered by this Warranty within thirty 30 days following such failure d There has been no misuse abuse or negligence with respect to the Product on the part of the OWNER Waiver COWAY s failu...

Страница 28: ...http www coway com 1210229 002 MADE IN KOREA...

Отзывы: