Run Function (Patient Monitoring) in Normal Mode
Operator's Manual
6-21
To adjust the USB storage rate, press the HOME
key to display the Main screen, then perform
the following navigation bar options:
In the User configuration menu, select
NEXT
to scroll to
USB STORAGE
. Select the
INCREASE
and
DECREASE
options to adjust the storage rate. The time scale range options are: 5, 30, and 60 sec-
onds. The default rate is 5 seconds (see section
When finished, press the HOME
key to exit the User configuration menu and return to the
Main screen.
6.5.8
Event Mark List
Note:
For quicker access to parameters on page 2 of the User configuration menu, select
PREVIOUS
to wrap
around from the top to bottom of page 1, then select
NEXT
to access page 2.
An OR event mark list, ICU event mark list, vascular event mark list or NICU event mark list may be
set for the user to mark events during the case. To determine which event mark list appears in Run
function, press the HOME
key to display the Main screen, then perform the following naviga-
tion bar options:
In the User configuration menu, select
NEXT
to scroll to
EVENT MARK LIST
. Select the
INCREASE
and
DECREASE
options to choose the appropriate list.
When finished, press the HOME
key to exit the User configuration menu and return to the
Main screen. When accessing the event mark option from the Main screen, the set list should
appear.
BASELINE MENU
EVENT MARK
ALARM AUDIO ON/OFF
NEXT MENU
OUTPUT SELECT
USER CONFIGURATION
TIME SCALE
NEXT MENU
NEXT
PREVIOUS
OFF
ON
NEXT
PREVIOUS
INCREASE
DECREASE
NEXT
PREVIOUS
INCREASE
DECREASE
BASELINE MENU
EVENT MARK
ALARM AUDIO ON/OFF
NEXT MENU
OUTPUT SELECT
USER CONFIGURATION
TIME SCALE
NEXT MENU
NEXT
PREVIOUS
OFF
ON
NEXT
PREVIOUS
INCREASE
DECREASE
NEXT
PREVIOUS
INCREASE
DECREASE
Содержание INVOS 5100C
Страница 1: ...Operator s Manual INVOS Regional Saturation Patient Monitoring System Model 5100C...
Страница 12: ...Page Left Intentionally Blank x Operator s Manual...
Страница 26: ...Introduction Page Left Intentionally Blank 1 14 Operator s Manual...
Страница 30: ...Product Overview Page Left Intentionally Blank 2 4 Operator s Manual...
Страница 46: ...Installation Page Left Intentionally Blank 3 16 Operator s Manual...
Страница 50: ...Quick Setup Page Left Intentionally Blank 4 4 Operator s Manual...
Страница 142: ...Database Operational Mode and Area Under the Curve Page Left Intentionally Blank 8 24 Operator s Manual...
Страница 164: ...Specifications Page Left Intentionally Blank A 12 Operator s Manual...
Страница 170: ...Clinical Studies Page Left Intentionally Blank B 6 Operator s Manual...
Страница 176: ...Glossary Page Left Intentionally Blank C 6 Operator s Manual...
Страница 177: ......