D1H4B-200
USER MANUAL
v1.0
1723 W. 4th Street Tempe Arizona 85281
P
: 800.638.6104 |
F
: 480.966.6728 |
E
www.covid.com
Page 9
7. ASCII Commands
This product also supports ASCII command control. Connect the RS-232 port of the product to a PC with
a 3-pin phoenix connector cable. Then, open a Serial Command tool on PC to send ASCII commands to
control the product. The ASCII command list about the product is shown as below.
ASCII Commands
Serial port protocol. Baud rate: 115200, Data bits: 8bit, Stop bits:1, Check bit: 0Power Indicator When the receiver is powered
on, the power indicator will be on.
x - Parameter 1
y - Parameter 2
! - DelimiterService port
Command Code
Function Description
Example
Feedback
Default Setting
Power
s power z!
Power on/off the device,z=0~1
(z=0 power off, z=1 power on)
s power 1!
Power on
System Initializing...
Initialization Finished!
FW version x.xx.xx
power on
r power!
Get current power state
r power!
power on/power off
s reboot!
Reboot the device
s reboot!
Reboot…
System Initializing...
Initialization Finished!
FW version x.xx.xx
System Setup
help!
List all commands
help!
r type!
Get device model
r type!
HDC-SPB14H150
r status!
Get device current status
r status!
Get the unit all status:
power, in/out
connection, edid mode
r fw version!
Get Firmware version
r fw version!
MCU BOOT: Vx.xx.xx
MCU APP: Vx.xx.xx
r link in!
Get the connection status of
the input port
r link in!
HDMI IN: connect
r link out y!
Get the connection status of
the y output port, y=0~5(0=all,
1~4=HDBT 1~4, 5 = loop out)
r link out 1!
hdmi loop out:
connect
hdbt output 1: connect
s reset!
Reset to factory defaults
s reset!
Reset to factory
defaults
System Initializing...
Initialization Finished!
FW version x.xx.xx