Factory Setting
COUNTER CMD
FW Version
AUTO BLOWOFF
L1/h1
L2/h2
UNIT
DIAG ECO
VII - FUNCTIONS SYNOPTIC
Keypad locking/unlocking:
UnL
/
Loc
(see IX-B)
Electronic manual controls
(see chap. VIII)
Back to “factory” settings:
FAC
(see XII-4)
Cycle number display:
ct1
/
ct2
/
ct3
(see X-A)
Firmware version:
Fir
(see X-B)
Threshold 1 setting:
L-1
/
h-1
(see XII-1)
Threshold 2 setting:
L-2
/
h-2
(see XII-2)
Choice of vacuum level display unit:
uni
(see IX-1)
Pct
(%),
-ba
(mbar),
-iH
(inHg).
Activation of "anti-pulsation" DIAG ECO:
Eco
(see XII-3) or auxiliary output setting
AnA
/
dEF
(see IX-2)
Activation and setting of timed
automatic blow-off:
Abl
(see IX-3)
Input/Output switching type. Can be set to
PnP
(by default) or
nPn
(see IX-4).
Factory Setting
COUNTER CMD
FW Version
AUTO BLOWOFF
L1/h1
L2/h2
UNIT
DIAG ECO
VII - MENÜ-ÜBERSICHT
Tastaturverriegelung/-entriegelung:
UnL
/
Loc
(siehe IX-B)
Manuelle elektronische Steuerung
(siehe VIII)
Rücksetzung auf werkseitige Einstellung:
FAC
(siehe XII-4)
Anzahl der Zyklenzahl:
ct1
/
ct2
/
ct3
(siehe X-A)
Firmware-Version:
Fir
(siehe X-B)
Einstellung des Grenzwerts 1:
L-1
/
h-1
(siehe XII-1)
Einstellung des Grenzwerts 2:
L-2
/
h-2
(siehe XII-2)
Auswahl der Anzeigeeinheit für das Vakuum-
niveau:
uni
(siehe IX-1)
Pct
(%),
-ba
(mbar),
-iH
(inHg).
Aktivierung der „Anti-Pulsierung“ DIAG ECO:
Eco
(siehe XII-3) oder Parametrierung des
Hilfsausgangs
AnA
/
dEF
(siehe IX-2)
Aktivierung und Parametrierung des automa-
tischen zeitverzögerten Abblasens:
Abl
(siehe IX-3)
Der Schaltmodus der Ein- / Ausgänge ist
in
PnP
(Standard) oder
nPn
(siehe IX-4)
konfigurierbar.
VII
2s
3s
CTR
Vacuum
CMD
L1
h1
CTR
Vacuum
Pilot
FW Version
IHM
HMI
&
Factory Setting
&
3s
3s
2s
2s
CTR
Blow
Pilot
2s
L2
h2
%
mbar
inHg
UNIT
ON
OFF
DIAG ECO
PNP
NPN
TYPE
0.1s
OFF
ON
AUTO BLOWOFF
3s
Electronic
manual override
Vacuum
Blow-off
888.888.888
888.888.888
888.888.888
8.8
3
VIII
1
3s
2
4
5
10s
VIII - ELECTRONIC MANUAL CONTROLS
The LEMAX vacuum pumps have electronic manual control of the
vacuum and blow-off solenoid valves.
This manual control is only available after the keypad is unlocked
(chap. IX-B).
1- Pressing once on
−
for 3 sec. switches into manual command
mode.
2-
mAn
appears on the display.
3- Pressing once on
+
activates the vacuum solenoid valve (“vacu-
um” status indicator lights up green on the dialogue panel)
or press once on
−
activates the blow-off solenoid valve (“blow-off”
status indicator lights up orange on the dialogue panel).
4- Wait 10 sec. or press
M
allows you to leave this mode.
5- Return to
00
vacuum level display.
VIII - MANUELLE ELEKTRONISCHE
STEUERUNG
Die Vakuumpumpen LEMAX verfügen über eine manuelle
elektronische Steuerung des Vakuums und Abblasens durch ein
Magnetventil.
Für diese manuelle Steuerung muss zunächst einmal die Tastatur
entriegelt werden (Kap. IX-B).
1- 1 Druck auf
−
während 3 s zum Umschalten in die manuelle
Steuerung.
2- Auf der Anzeige erscheint
mAn
.
3- 1 Druck auf
+
aktiviert das Magnetventil zur Steuerung des
Vakuums (Statusanzeige „Vakuum“ im Dialogfeld leuchtet grün)
oder 1 Druck auf
−
aktiviert das Magnetventil zur Steuerung des
Abblasens (Statusanzeige „Abblasen“ im Dialogfeld leuchtet
orange).
4- 10 s warten oder auf
M
drücken, um den Modus zu beenden.
5- Für das Vakuumniveau wird erneut
00
angezeigt.
Electronic
manual override
Electronic
manual override
TYPE
TYPE
- 5 -