FIGURE 9, Item A shows another method of installing an LR-01 pellet stove. The flue pipe is
extended a minimum of 18” past an existing damper with a seal plate installed at or above the damper.
Although this is an approved method of installation, Country Flame strongly recommends that all
pellet stove chimney pipe be extended to the top of the chimney and properly terminated and capped to
ensure optimum performance
FIGURE 9: MINIMUM FLUE VENT CHIMNEY INSTALLATION
NOTE: Installing a fresh air inlet line can be similar to the illustration accompanying the
freestanding units or the line can be run out of the top of the chimney. Attach a screen to keep
out debris. For best efficiency, locate air inlet 24” (607mm) or more from exhaust vent pipe.
5.
WARNING
: When installing unit as an insert into an existing fireplace, DO NOT remove any
bricks or mortar from the old fireplace.
6.
While running flue pipe up past the existing damper in the fireplace, lock the old damper into
the open position.