PLEASE NOTE:
Do not use a 240 volt pump or other electrical appliances
where they could be affected by water from the unit.
TYPICAL INSTALLATION
The supplied 1.2 meter LPG hose and regulator assembly
connects to a 9 kg LPG cylinder (maximum size). The
water heater is then located 1.4 meters from ground level
to the connection points as shown above. Water pump and
fresh water tank are to be located in a convenient position
as shown.
Tools required: 2 x Shifting Spanners
List of supplied parts:
Gas Hose and Regulator.
2 x D Cell Batteries.
Shower Hose and Shower Rose.
Gas regulator must be protected from water. Water Pump
installation. (Pump and tank not supplied)
1. Place the required 12 Volt sealed water pump close to
the fresh cold water tank (minimum 20ltr) and the
water heater. Wire the pump according to the
manufacturer’s instructions and in regards to water
protection.
2.
Run a 3/8” or ½” pipe from the water heater WATER
IN connection to the location of the pump.
3.
Run a 3/8” or ½” pipe from the outlet of the fresh water
tank to the location of the pump.
4.
Inspect every joint and pipe run for leaks.
AFTER USE, TURN THE GAS CYLINDER
VALVE OFF, WAIT FOR THE FLAME TO GO
OUT, THEN TURN THE APPLIANCE CONTROL
VALVE(S) OFF.