Costway EP23475 Скачать руководство пользователя страница 8

 

14

PLACE FOR USE   

(1) 

Because the machine distributes hot air, please don’t place or 

operate in a narrow place. 

(2) 

In case of dangerous leak, don’t work the machine in a humid place. 

(3) 

Don’ t place the machine in a sunlit corner otherwise the unit might 

shut down due to the overheat and the color of the machine may 

soon fade out.

 

HELPFUL HINTS 

The unit is fitted with a special thermal cut off device. 

Please ensure the unit is not placed against objects which will 

obstruct air intake e.g. furniture or curtains as this will affect it's 

performance dramatically.

 

 
TROUBLE SHOOTING

 

 

 

Problem Cause

 

Trouble shooting

 

E1 

Electrical short on both 
temperature sensor and PCB 

Contact maintenance station to repair 

E2 

Electrical short on both 
temperature sensor and PCB

 

Contact maintenance station to repair 

E4 

Indicates water tank full 

 

User needs to pull out the rubber 
stopper which is located at the bottom 
of the unit, to drain the water away. 

 

 

15

 

 

 

 

 

 

 

 

 

This marking indicates that this product should not be disposed with 
other household wastes throughout the EU. To prevent possible 
hazards to the environment or human health from uncontrolled 
waste disposal, please recycle it to prove the sustainable reuse of 
material resources. Please ask return and collection systems or 
contact the retailer where the product was purchased to return your 
used device, they can recycle products safely.

 

SPECIFICATION

 

 

 

 

 

 

 

 

 

MADE IN CHINA 

(CE) N 842/2006: 
R410A is a kind of fluorinated greenhouse gases covered by 
the Kyoto Protocol. 
Its total global warming potential (GWP) is 2088.

 

 

 

Model No.

 

EP23475

 

Power Source

 

120V~60Hz 

Rated Power (EN60335)

   

Cooling  

 

1100W 

Cooling Capacity

 

10000BTU/H 

Moisture Removed(86

 RH80%)

 

50liters/day 

Refrigerant  

R410A 

Содержание EP23475

Страница 1: ... explosive or corrosive atmosphere 4 Operate this unit in an ambient of 95 degree centigrade or less 5 Clean air filter periodically to enjoy the most efficient cooling 6 When the unit is shut off please wait at least 3 5 minutes before restarting this is to prevent the compressor from being damaged 7 This unit needs at least 7 Amps of electricity to have its compressor operational To avoid the ho...

Страница 2: ...he length less than 400 mm 2 A distance of 500mm minimum must be kept between the filter side of the unit and wall or any other obstacles 3 When this appliance starts to defrost the word DF will be displayed on the LED 3 CONGRATULATIONS ON YOUR SELECTION OF A QUALITY PORTABLE AIR CONDITIONER This Air Conditioner has been designed and manufactured to the highest standards of modern engineering Our ...

Страница 3: ...Inner joint of exhaust hose and exhaust pipe out of the base as shown in the figure 6 Please install the exhaust hose on the product before use CONTENTS 1 Air conditioner unit 2 Exhaust hose with exhaust hose outer joint inside 3 Exhaust hose inner joint 4 Upper Foam 5 Bottom Foam Base 6 Remote controller 7 Batteries 8 User Manual 5 NAME OF THE PARTS 1 Control panel 2 Remote control receiver 3 Coo...

Страница 4: ...st pipe inner joint with the product as shown in the figure 7 CONTROL PANEL AND FUNCTION INTRODUCTION 1 POWER KEY Press to turn unit ON or OFF 2 FUNCTION Press this key to select cooling dehumidifying or fan 3 TEMPERATURE REGULATION KEY UP Cooling mode add 33 8 by pressing the button once until 86 at highest 4 TEMPERATURE REGULATION KEY DOWN Cooling mode reduce 33 8 by pressing the button once unt...

Страница 5: ...lly after the setting time is over 1 Press the TIMER key at operating status to set the time you desired 2 Once the set hour has come to an end the unit will turn off automatically 3 Press the POWER key before the time out the setting time will be canceled and the unit will turn off Note In dehumidifying function this key is invalid because the unit is defined to low speed in dehumidifying mode 9 ...

Страница 6: ... install the drain pipe Please make sure the drain hole is installed with rubber cap 2 When the product is dehumidifying pull the rubber cap from the drain hole and install a suitable drain pipe Please remove the rubber cap to enhance the dehumidification ability When the water tank is full E4 will be displayed on the display panel Please remove the rubber cap of the drain hole to drain out the wa...

Страница 7: ...ith soft cloth Please pull the filter up slightly according to the direction as shown in the figure to remove the filter screen for cleaning 13 WINDOW KIT INSTALL Install the Exhaust Hose and the Adjustable Window Slider Kit as depicted in Fig 1 Fig 1a POWER SUPPLY 1 Confirm the correct power 2 Insert the plug into the outlet firmly In order to prevent any dangerous leakage 3 Don t pull power wire...

Страница 8: ...nd PCB Contact maintenance station to repair E4 Indicates water tank full User needs to pull out the rubber stopper which is located at the bottom of the unit to drain the water away 15 This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible hazards to the environment or human health from uncontrolled waste disposal please r...

Отзывы: