background image

Instruction Manual: COSTAR® 9SS, 9V CO Safety Shutoff 

QGI P/N 099-0043-01 REV 11/07/01 

Page 2 of 4 

This device may not activate at low CO levels.  The Occupational Safety and Health Association (OSHA) has established that 
continuous exposure to levels of 50 ppm should not be exceeded in an 8-hour period.  This detector will respond to CO 
concentrations of 50 ppm or greater.  Individuals with medical problems may consider using detection devices with lower CO 
detection capabilities. 
 
Never spray the unit with water or cleaning solutions of any kind.  They may damage the detector.  Ventilate the area where unit 
is installed when household cleaning supplies or similar contaminants are used.  Do not paint the unit. 
 
Test your detector at least once a week during periods of operation.  Manufacturer recommends replacement of detector six years 
after date of purchase. 

 

A. INSTALLATION 

CAUTION

: Before installing your carbon monoxide safety shutoff product, review your appliance owner’s 

manual for the location of the cast control valve and the thermocouple. 

1. 

Disconnect the thermocouple from the control valve on your gas appliance.

 

2. 

Thread the thermocouple interrupter provided into the thermocouple inlet of the control valve until it just 
bottoms out in the valve.  DO NOT OVERTIGHTEN. (Figure 1)

 

3. 

Insert the terminal connections at the end of the FET assembly into the contacts of the thermocouple 
interrupter with the arrow on the FET assembly pointing toward the control valve. (Figure 1)

 

4. 

Thread the thermocouple into the rear of the thermocouple interrupter and tighten.

 

5. 

Remove the COSS unit from the sealed bag.

 

6. 

Remove the plastic cover of the unit from its base.

 

7. 

Locate your unit on any wall, ceiling, or other smooth surface within cord’s reach (approx. 6 ft.) of the 
appliance.  Connect the COSS plug wire to the detector.

 

8. 

Connect the 9-volt battery as shown in Figure 2.

 

9. 

Re-attach the cover back onto its case.

 

WARNING

: Do not run the unit behind heavy draperies or furniture, within 5-feet of any cooking appliance or in 

direct sunlight. 
 

B. OPERATION 

CONDITION RED 

L.E.D. 

BEEPER 

Normal 

Flash every 30 seconds 

No Beep 

Low Battery 

Flash every 30 seconds 

Beep every 30 seconds 

Fault Condition 

2 flashes every 30 seconds 

2 beeps every 30 seconds 

Shut Off 

2 flashes every 30 seconds 

Double Beep every 3 seconds 

TESTING THE SYSTEM: 

Push and hold the test button until “beep” is heard, then release button.  All functions are tested for correct operation.  
At the end of the test, the unit will sound a three second test confirmation “beep” and assume normal operation.  
Appliance will shut down following normal test operation

.  Appliance must be re-lit to restore function.  

WARNING: Abnormal test function will result in appliance not being shut down.  Cause for abnormal test must 
be investigated.

 

 

NORMAL OPERATION: 

Содержание 9SS

Страница 1: ...n Ph D President Quantum Group Inc The CO Safety Shutoff COSS is designed to give visual and audible signals and shut your appliance down if carbon monoxide CO reaches levels predetermined to be unhealthy or dangerous IMPORTANT SAFETY INFORMATION WHAT SHOULD I DO IF YOU SMELL GAS Do not try to light any appliance Do not touch the electrical switch Immediately call your gas supplier from a neighbor...

Страница 2: ...the terminal connections at the end of the FET assembly into the contacts of the thermocouple interrupter with the arrow on the FET assembly pointing toward the control valve Figure 1 4 Thread the thermocouple into the rear of the thermocouple interrupter and tighten 5 Remove the COSS unit from the sealed bag 6 Remove the plastic cover of the unit from its base 7 Locate your unit on any wall ceili...

Страница 3: ...e cannot be restarted until CO dissipates and the danger is eliminated REPLACING THE BATTERY 1 Remove the plastic cover of the CO Safety Shutoff from the base 2 Remove the battery and replace it with the new one Figure 2 3 Re attach cover 4 Test CO Safety Shutoff for proper operation as described above by pushing test button Repeat weekly Use on the following 9 volt alkaline batteries for replacem...

Страница 4: ... A DURATION LONGER THAN THAT OF THIS WRITTEN WARRANTY EXCEPT AS REQUIRED BY LAW INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR AGAINST INFRINGEMENT OR ANY EXPRESS OR IMPLIED WARRANTY ARISING OUT OF TRADE USAGE OR OUT OF A COURSE OF DEALING OR COURSE OF PERFORMANCE Quantum Group Inc has not authorized any other party to extend any other warrantie...

Отзывы: