16
7 - MAINTENANCE
7.1 - Maintenance
WARNING! The maintenance of the device must
be carried out only by a professionally qualified engineer.
7.1.1 - Electronic anode rode
status check
All the storage tanks have a protective electronic anode rode
fitted as standard, for correct operation just check the LEDs
present on it. The table showing how to interpret the LEDs
is given below:
WARNING! The device includes two LEDs that
signal in real time the protection status or any eventual
malfunctions. See the following table for the visual
warnings.
L1 (RED)
L2 (GREEN)
DEVICE STATUS
SOLUTION
OFF
OFF
Not powered
Check power supply to the device
OFF
ON
Operating - Correct position
/
ON
OFF
Anode rode short circuit
Anode rode not connected
Check the metal part of the anode rode is not in
contact with the metal parts of the storage tank;
Check the connection of the anode rode;
Check it is correctly earthed;
Table of electronic anode rode operation