15
IMPORTANT:
Local Codes may vary; installation of electrical connections and
grounding must comply with all applicable local codes.
If local codes permit grounding through the electrical supply neutral, connect
both the white neutral wire and the green ground wire from the oven to the
white neutral electrical supply wire.
ELECTRICAL REQUIREMENTS - CANADA ONLY
Electrical Shock Hazard
Electrically ground range.
Failure to do so can result in death, fire or electrical shock.
Electrical Grounding Instructions
This appliance is equipped with a four-prong grounding plug for your
protection against shock hazard and should be plugged directly into a
properly grounded receptacle. Do not cut or remove the grounding prong
from this plug.
•
A circuit breaker is recommended.
•
Allow 3 ft - 6 ft (0.9 m - 1.8 m) of slack in the line so that the range can be
moved if servicing is ever necessary.
•
A UL listed conduit connector must be provided at each end of the power
supply cable (at the range and at the junction box).
•
The electrical supply should be a 3-wire or 4-wire, single-phase AC. Install
a suitable conduit box (not furnished). An appropriately sized, U-listed
conduit connector must be used to correctly attach the conduit to the
junction box.
•
Wire sizes and connections must conform with the rating of the range.
WARNING