3 1
R E T U R N T E M P E R A T U R E M A I N T E N A N C E - D N 2 5 / D N 3 2
2 . 5 A C T U AT O R
Assembly of the actuator:
1.
Turn the adjusting knob of the mixing
valve into position 0 (see figure
on the left).
2.
Set the actuator to manual mode by
turning the selector switch.
3.
Turn the adjusting knob of the actuator
to the left (see figure on the left).
4.
Mount the inner insulation elements
(see page 14) before putting the
actuator on the adjusting knob of the
mixing valve.
5.
Connect the flow sensor with the
actuator.
6.
Set the automatic operation mode and
the desired flow temperature at the
actuator.
Rotation lock
0
Selector
switch
Scale: small
Scale: large