Cosmed microQuark Скачать руководство пользователя страница 35

 

Service - Warranty 

 

Warranty and limitation of liability  

COSMED provides a one year limited warranty from the date of the original sale of the product. COSMED products are guaranteed to be free from 
defect upon shipment. Liability for products covered by this warranty is limited to the replacement, repair or issuance of a credit for the cost of a 

defective product at the discretion of COSMED.  
The following conditions must exist for the warranty to apply:  
1) COSMED is promptly notified in writing by the buyer upon the discovery of defect. 
2) The defective product is returned to COSMED with transportation charges prepaid by the buyer.  
3) The defective product is received by COSMED no later than four weeks after the last day of the one year warranty period.  
4)  COSMED’s examination of the defective product verifies  that  the  defect was not caused by misuse, neglect, improper installation or an 

unauthorized repair or alteration.  
If the product is manufactured by a third-party, the warranties provided by the third-party manufacturer will be the only ones available for the 

buyer. COSMED hereby disclaims any warranties or liabilities arising from defects or damages to and/or caused by products manufactured by a 
third-party. The buyer must obtain written authorization from COSMED prior to the repair or alteration of any COSMED products. Failure to obtain a 
written authorization will result in a void of the warranty. 
The limited warranty shall not be enlarged, diminished or modified by the renderings of technical service from COSMED’s agents or employees 
when the product is ordered or following the use of the product(s). 

 

Return goods policy for warranty or non warranty repair 

Products shipped to COSMED for repair are subject to the following conditions: 
1.

 

Products may only be returned upon receiving a receipt which includes the 

Service Return Number (SRN)

 from COSMED S.r.l. 

2.

 

The SRN report and packing list should be placed on the outside of the package. 

3.

 

Returned goods must be shipped with freight and insurance charges prepaid. 

Collect shipments will not be accepted

4.

 

The following list of products is not eligible for return unless proven defective. 
-  Special order items. 

-  Expendable products. 

-  Products held over 30 days after the COSMED invoice date. 
-  Used products not in the original shipping containers. 

-  Goods which have been altered or abused in any way. 

5.

 

The following parts are not covered by warranty: 
- Consumables. 

- Fragile glass or plastic parts. 
- Rechargeable batteries.  

- Damages due to inappropriate use of the device.  

 

Repair Service Policy 

Goods returned to seller for non-warranty repair will be subject to conditions 1, 2, 3, 4. 
Returned goods requiring customs documents (Pro-forma Invoice and Customs Paper) should comply with the Italian law. 

 

The shipment must qualify as a temporary export. 

 

Any goods returned to COSMED without customs papers will not be accepted. 

For European Community members: 

The Pro-Forma invoice should include the following: 

 

Number 

 

Description of the product 

 

Quantity 

 

Appendix - Service - Warranty - 33 

Содержание microQuark

Страница 1: ...Manuale Utente User Manual Manuel d utilisation Benutzerhandbuch Manual del Usuario microQuark PC based Spirometer...

Страница 2: ......

Страница 3: ...ransmitted inany form withoutthe expressed writtenpermissionof COSMED Srl Eachcopy of theCOSMED Softwarecanonly beinstalled ononecomputer Excel is aregistered trademark of MicrosoftCorporation DBIIIis...

Страница 4: ...2...

Страница 5: ...e 9 EMC 10 Overview of the manual 14 Introduction 15 MicroQuark overview 16 MicroQuark unit 16 Theflowmeter 16 Paper mouthpieces 17 Antibacterial filters 17 Noseclips 17 Installation 19 Beforestarting...

Страница 6: ...razionedi conformit 32 Service Warranty 33 Warranty and limitationof liability 33 Returngoods policy for warranty or nonwarranty repair 33 Repair ServicePolicy 33 Privacy Information 35 Personal datat...

Страница 7: ...Getting started...

Страница 8: ...nd trained personnel Environmental and electrical conditions in which the device operates should be in compliance with the specifications of this manual In particular grounding reliability and leakage...

Страница 9: ...equipment 14 The device should not be used adjacent to or stacked with other equipment If this is necessary you must verify that the device continues to operatenormally intheconfigurationinwhichit wil...

Страница 10: ...sts Hyperventilationsyndrome Contraindications for Bronchial Provocation testing Bronchial Provocation testing must be executed under the direction of a physician Testing is considered safe when execu...

Страница 11: ...d be operated under normal environmental temperatures and conditions which are defined as follows IEC 60601 1 EN 60601 1 Temperatures range 10 C 50 F and 40 C 104 F Relativehumidity range 30 to 90 not...

Страница 12: ...The device uses RF energy only for its internal function Therefore its RF emissions are very low and arenotlikely tocauseany interferencein nearby electronic equipment RF emissions CISPR 11 Class B T...

Страница 13: ...common mode 1kV differential mode 2kV commonmode Mains power quality should be that of a typical commercial or hospital environment Voltagedips short interruptions and voltage variations onpower suppl...

Страница 14: ...mitters as determined by an electromagnetic site surveya should be less than the compliancelevel ineachfrequency rangeb Interference may occur in the vicinity of equipment marked withthe following sym...

Страница 15: ...cy oftransmitter m 150 kHz to 80 MHz d 1 17 P 80 MHz to 800 MHz d 1 17 P 800 MHz to 2 5 GHz d 2 33 P 0 01 0 12 0 12 0 23 0 1 0 37 0 37 0 74 1 1 17 1 17 2 33 10 3 70 3 70 7 38 100 11 70 11 70 23 33 For...

Страница 16: ...equiredtoproperly install thedevice Systemmaintenance Describes system maintenanceprocedures Appendix Contains information regarding the warranty treatment of personal data reference standards technic...

Страница 17: ...intelligent flowmeter that connected to a Personal Computer laptop or desktop turns itinacompletespirometric lab The system is composed by the turbine flowmeter the measurement and data elaboration d...

Страница 18: ...The air passing through the helical conveyors takes a spiral motion which causes the rotation of the turbine rotor The rolling blade interrupts the infrared light beamed by the two diodes of the read...

Страница 19: ...infection control However regular cleaning and decontamination of lung function equipment should always beperformed Note The use of antibacterial filters is recommended even when using disposable mout...

Страница 20: ......

Страница 21: ...Installation...

Страница 22: ...should assure that the package contains the items listed in the packing list enclosed with the device If there are any missing or damaged parts you should contactCosmed s technical assistance Options...

Страница 23: ...USBplug Theunitis turnedon off automatically by thePC Insertthe turbineand besureto pushthe turbineup totouchtheend of theholder MicroQuark connects tothePCas showninthefollowing picture 1 microQuark...

Страница 24: ...Piani di Monte Savello 37 00041 AlbanoLaziale Rome ITALY Voice 39 06 931 5492 Fax 39 06 931 4580 email customersupport cosmed it Internet http www cosmed com Complaints feedback and suggestions If yo...

Страница 25: ...System maintenance...

Страница 26: ...oQuark arenon toxic and posenosafety risk tothepatientor operator Prior tothedevicecleaning disinfectionand inspectionit is necessary to switchoff the deviceand todisconnectadapters from thesupply mai...

Страница 27: ...oplet nuclei are likely to be encountered proper attention to environmental engineering controls suchas ventilation air filtration or ultravioletdecontaminationof air should beused topreventdiseasetra...

Страница 28: ...or partial disassembly for cleaning and disinfection It is the responsibility of the user health care personnel for ensuring that the cleaning methods recommended can be duplicated in their environmen...

Страница 29: ...dations inthis sections havebeen retrieved from William A Rutala Ph D M P H David J Weber M D M P H and the Healthcare Infection Control Practices Advisory Committee HICPAC Guidelinefor Disinfectionan...

Страница 30: ...epropeller rotates freely evenwith alow speed air flow 6 Connect the turbineto thereader Precautions to take when cleaning disinfecting and drying the turbine Donot exposethe turbineto highheat or to...

Страница 31: ...of cables plugs and any other visible part by means of simpleinspection whentheequipmentis switched off and adapters or electrical feeders aredisconnected from thesupply mains Extract the turbine from...

Страница 32: ......

Страница 33: ...Appendix...

Страница 34: ...ts of theAnnex I of theMedical DeviceDirective93 42 EEC areclassified inClass IIa their design manufacturing and final checks are performed according the Cosmed s Quality System conform to ISO 9001 20...

Страница 35: ...navoid of the warranty The limited warranty shall not be enlarged diminished or modified by the renderings of technical service from COSMED s agents or employees whentheproductis ordered or following...

Страница 36: ...39 06 9314580 E mail customersupport cosmed it USA contact COSMED USA Inc 2211 NorthElston Suite305 ChicagoIL 60614USA Phone 1 773 645 8113 Fax 1 773 645 8116 email usa sales cosmed it Toensurethatyou...

Страница 37: ...l invoices e Toprovideinformationtotheselected business partners needed tosupply your service How your personal data is treated Your personal data will be stored in an electronic format and protected...

Страница 38: ...ent must becollected separately according to the European Directive 2002 96 EEC Otherwiseitcancausedangerous consequences for theenvironmentand human health Thecrossed outwheeled binmeans thattheprodu...

Страница 39: ...device Devicenotsuitableinthepresenceof flammableanaesthetics Continuous functioning equipment EMC Thesystem meets the Standard IEC 60601 1 2 Quality Assurance UNIEN ISO 9001 2008 Registration n 387 A...

Страница 40: ...Flowmeter Bidirectional digital turbine Flow Range 0 16 l s VolumeRange 12l Accuracy 2 or 20ml s Resistance 0 6cmH2O l s 14l s Mouthpieces 31 and 22 mm Dimensions 150x 45 x 53mm Weight 77g 38 Appendix...

Страница 41: ...Standard for healthy non smoking adults ARRD Vol 10 3 p 57 67 1971 Pereira Brazil Pereira CAC Barreto SP Sim es JG Pereira FWL Gerstler JG Nakatani J Valores de Refer ncia para Espirometria em uma amo...

Страница 42: ...pressures in adults normal values and their relationship to determinants of respiratory function Bull Eur Physiopathol Resp 23 435 439 Automatic diagnosis algorithm Reference Lung FunctionTesting sele...

Страница 43: ...eadeeper breath dFVC 200ml and 5 bestFVC Blow outfaster dFEV1 200ml and 5 FEV1 Thatwas a good test Noerrors FVCreproducible Diff 2maxFVCwithin 0 2l FEV1reproducible Diff 2maxFEV1within0 2 l PEF reprod...

Страница 44: ...D Stanescu D Rodenstein C Veriter Reassesment of interrupter technique for measuring flow resistance in human J Appl Physiol 67 3 933 937 1989 Oximeter National Lung HealthEducationProgram NLHEP Guide...

Страница 45: ......

Страница 46: ...www cosmed com COSMEDsrl ViadeiPianidiMonteSavello37 AlbanoLaziale Rome 00041ITALY O 3906931 5492 F 3906931 4580 info cosmed com cosmed com...

Отзывы: