Series operation with V1 and V2 is available by connecting the

outputs of the unit as shown below. Output current in series con-

nection should be lower than the lowest output current of the unit.

Series operation with other model is not possible.

Parallel operation is not possible.

l

MMB50A

(1)Mounting method

(2)Derating curve

Note:

In the hatched area, the specification of Ripple, Ripple Noise is

different from other area.

MMB-9

3 Series Operation and

Parallel Operation

4 Assembling and

Installation Method

2.6 Isolation

n

For a receiving inspection, such as Hi-Pot test, gradually in-

crease(decrease)the voltage for the start(shut down). Avoid using

Hi-Pot tester with the timer because it may generate voltage a

few times higher than applied voltage, at ON/OFF of a timer.

If the unit is tested on the isolation between input & output and

output & FG, output terminals must be shorted.

4.1 Installation method

4.2 Derating

n

n

n

When two or more power supplies are used side by side, position

them with proper intervals to allow enough air ventilation. Ambient

temperature around each power supply should not exceed the

temperature range shown in derating curve.

The operative ambient temperature is different by with/without

case cover or mounting position. Please refer drawings as below.

When unit mounted except below drawings, it is required to con-

sider ventilated environment by forced air cooling or tempera-

ture/load derating. For details, please consult our sales or engi-

neering departments.

10

0

-10

55

45

35

25

65

55

45

35

25

70

60

50

40

30

Forced air (0.5m /min)

3

Convection

100

80

60

40

20

0

C mounting

B mounting

A mounting

Ambient temperature [ ]

Without
case
cover

Load

factor

[%]

10

0

-10

60

50

40

30

70

60

50

40

30

70

60

50

40

30

With
case
cover

Forced air (0.5m /min)

3

Convection

100

80

60

40

20

0

C mounting

B mounting

A mounting

Ambient temperature [ ]

Load

factor

[%]

MMB

Instruction Manual

AC-DC Power Supplies Enclosed type

June 29, 2011