n
n
n
In case of metal chassis, keep more than 8mm for the part of
to
insulate between lead of component and metal chassis. If it is
less than 8mm, insert the insulation sheet between power supply
and metal chassis.
The mounting screw should be M3. The hatched area shows the
allowance of metal parts for mounting.
Keep isolation distance between metal parts for mounting and in-
ternal components.
4.3 Mounting screw
l
LCC30A
5 Peak Loading
6 Ground
7 Others
n
Peak load current is possible to draw 10 seconds subject the aver-
age current should be less than the rated current. It will damage
devices inside the power supply when the peak load current con-
tinues more than 10 seconds.
n
When installing the power supply with your unit, ensure that the in-
put FG terminal or mounting hole FG is connected to safety
ground of the unit. However, when applying the safety agency,
connect the input FG terminal to safety ground of the unit.
n
n
n
This power supply is the rugged PCB type. Do not drop conduc-
tive objects in the power supply.
At light load, there remains high voltage inside the power supply
for a few minutes after power OFF. So at maintenance, take care
about electric shock.
This power supply is manufactured by SMD technology. The
stress to PCB like twisting or bending causes the defect of the
unit, so handle the unit with care.
LCC
CN1
CN1
CN1
Normal mounting
(A)
(B)
(C)
(Only when forced air)
CN1
CN1
CN1
(D)
(E)
(F)
CN1
CN2
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
unit [mm]
LCC-8
Instruction Manual
AC-DC Power Supplies Open Frame/Enclosed type
June 29, 2011