background image

EAC series

Small, common mode EMI/EMC Filters in 150kHz to 1MHz (1-Stage filter)

 EAC  -10  -472  -

O

 

Ordering information

*

 

The dimensions change when the option is set.

 

Refer to External view.

4

 

Features of EAC series

Circuit Diagram

Derating Curve

LINE

Case

: Mounting Plate

1

2

4

3

CY

CY

CY : Line to ground capacitor

LOAD

Small, common mode EMI/EMC Filters in 150kHz to 1MHz(1-Stage filter)

-

 Single Phase 250 VAC 

-

Small-size

 

-

Quick and easy push-down terminal

 

Just connect the wires,push-down and tighten

 

the screws with a screwdriver

Ambient Temperature [

C

]

Load Factor [%]

90

50

60

70

80

20

0

-40

40

-30

-20

100

80
60
40

55

Specifications

No.

Items

EAC-03-472

EAC-06-472

EAC-10-472

EAC-16-472

EAC-20-472

EAC-30-472

1

Rated Voltage[V]

AC 1

f

 250 / DC250

2

Rated Current[A]

3

6

10

16

20

30

3

Test Voltage (Terminal-Mounting Plate)

2,500 VAC (Cutoff Current = 20mA), 1minute at room temperature and humidity

4

Isolation Resistance (Terminal-Mounting Plate)

500 VDC 500M

W

 min at room temperature and humidity

5

Leakage current  125/250V 60Hz

0.5mA/1.0mA max

6

DC resistance

180m

W

 max

110m

W

 max

40m

W

 max

20m

W

 max

10m

W

 max

6m

W

 max

7

Safety agency approval temperatures

-25 to +85

C

 (Refer to Derating Curve)

8

Operating temperature

-40 to +85

C

 (Refer to Derating Curve)

9

Operating humidity

20 to 95%RH (Non condensing)

10

Storage temperature/humidity

-40 to +85

C

/20 to 95%RH (Non condensing)

11

Vibration

10 to 55Hz, 19.6m/s

2

 (2G), 3min. Period, 1hour each X, Y and Z axis

12

Impact

196.1m/s

2

 (20G), 11ms Once each X, Y and Z axis

13

Safety agency approvals

UL1283, CSA C22.2 No.8 (C-UL), DIN EN60939 VDE0565 Teil3-1, ENEC  (At only AC input)

14

Case size (without projection) /Weight

39

X

30

X

85 mm [1.54

X

1.18

X

3.35 inches] (W

X

H

X

D) /170g max (Option : -D refer to external view)

DIN rail installation type is option

The terminal cover is retracted inside the unit

1

 Model  Name

2

 Rated  Current

3

 Line to ground capacitor code:See table 1.1.

table1.1  Line to ground capacitor code

Code

Leakage Current

(Input 125/250V 60Hz)

Line to ground 
capacitor 
(nominal value)

681

 75.5  A/ 150  A max

680pF

102

  0.13 mA/ 0.25mA  max

1000pF

222

  0.25 mA/ 0.5  mA max

2200pF

332

  0.38 mA/ 0.75mA  max

3300pF

472

  0.5  mA/ 1.0  mA max

4700pF

*

 

When the line to ground capacitor code is 

different, the attenuation characteristic is 

different.

4

 Options

  D :DIN rail installation type

EA/ES-1

R

July 08, 2020