background image

2 Wiring Input/Output Pin

1 Connection for

  Standard Use

¡

In order to use the power supply, it is necessary to wire as shown 
in Fig.1.1 and external components in table1.1.

¡

Short the following pins to turn on the power supply.
-VIN RC1, +VOUT +S, -VOUT -S

   

Reference: 3.5  ”Remote ON/OFF” 

   

 

3.6  ”Remote sensing”

¡

The DBS Series handles only the DC input.
Avoid applying AC input directly.
It will damage the power supply.

¡

Operate with the conduction cooling(e.g. heat radiation from the 
aluminum base plate to the attached heat sink).

    Reference ”Derating” 

+

Heatsink

o

C

Cin

FG

RC1

-S

+VOUT

-VOUT

-VIN

+VIN

+S

Y

C

Load

F1

DC
input

Noise
filter

Fig.1.1 Connection for standard use

Table 1.1 External components

No. Symbol

component

Reference

1

F1

Input fuse

2.1  (1) ”External fuse”

2

C

Y

Primary decoupling capacitor 2.1  (2) ”Noise filter/

              Decoupling capacitor”

3

x

Noise filter

4

Cin

External capacitor on the input side 2.1 (3) ”External capacitor on the input side”

5

Co

External capacitor on the output side 2.2  ”Wiring output pin”

6

x

Heatsink

”Derating”

2.1 Wiring input pin

(1) External fuse

¡

Fuse is not built-in on input side. In order to protect the unit, install 
the normal blow type fuse on input side.

¡

When the input voltage from a front end unit is supplied to multiple 
units, install the normal blow type fuse in each unit.

Table 2.1 Recommended fuse(Normal-blow type)

Model

DBS100A / 150A DBS200B DBS400B DBS700B

Rated current

5A

3A

5A

10A

(2) Noise filter/Decoupling capacitor

¡

Install an external noise filter and a decoupling capacitor C

Y

 for 

low line-noise and for stable operation of the power supply.

¡

Install a correspondence filter, if a noise standard meeting is re-
quired or if the surge voltage may be applied to the unit.

¡

Install a primary decoupling capacitor C

Y

, with more than 470pF, 

near the input pins(within 50mm from the pins).

¡

When the total capacitance of the primary decoupling capacitor is 
more than 8800pF, the nominal value in the specification may not 
be  met by the Hi-Pot test between input and output.
In this case, it is that a capacitor should be installed between out-
put and FG.

(3) External capacitor on the input side

¡

Install an external capacitor Cin bVIN and -VIN input pins 
for low line-noise and for stable operation of the power supply.

   

DBS100A / 150A:more than 47μF

   

DBS200B:more than 0.1μF  

   

DBS400B / 700B:more than 0.33μF

¡

When the line impedance is high or the input voltage rise quickly 
at start-up(less than 10μs), install a capacitor Cin bVIN 
and -VIN input pins(within 50mm from pins).

   

DBS200B:more than 22μF            

   

DBS400B / 700B:more than 47μF

(4) Input voltage rang/Input current range

¡

The specification of input ripple voltage is shown as below.

   

Ripple voltage DBS100A / 150A:less than 10Vp-p 

   

DBS200B / 400B / 700B:less than 20Vp-p

¡

Make sure that the voltage fluctuation, including the ripple voltage, 
will not exceed the input voltage range.

¡

Use a front end unit with enough power, considering the start-up 
current Ip of this unit.

t

Ripple

voltage

time

Input voltage [V]

Input voltage range

Fig.2.1 Input voltage ripple

DC-DC Converters Bus Converter

-

Power Module Type

Instruction Manual

DBS-13

June 26, 2020

Содержание DBS100A

Страница 1: ...Thermal detection Thermal protection DBS 15 3 4 Inverter operation monitor DBS 15 3 5 Remote ON OFF DBS 15 3 6 Remote sensing DBS 16 3 7 Adjustable voltage range DBS 16 3 8 Isolation DBS 17 3 Function...

Страница 2: ...external noise filter and a decoupling capacitor CY for low line noise and for stable operation of the power supply Install a correspondence filter if a noise standard meeting is re quired or if the...

Страница 3: ...pins Table 2 2 Recommended capacitance Co F Model DBS100A DBS150A DBS200B DBS400B DBS700B Output voltage V 3 3 x 2200 6800 x 5 2200 2200 4700 x 7 5 x 2200 4700 x 12 1000 1000 2200 2200 13 8 1000 x x...

Страница 4: ...hiccup operation of power supply 3 2 Overvoltage protection The overvoltage protection circuit is built in The DC input should be shut down if overvoltage protection is in operation The mini mum inter...

Страница 5: ...current is drawn and the pattern may be damaged The pattern disconnection can be prevented by installing the pro tection parts as close as a load S S VOUT VOUT OUT Co Load Short at pin root Fig 3 4 C...

Страница 6: ...ty for equipment In parallel operation the maximum operative number of units is 11 Table 3 3 Recommended value of external potentiometer resistor No Adjustable range Number of unit External parts valu...

Страница 7: ...ration sensing wires should be connected between each units for the muster connection to a load Output current should be 10 or more of the total of the rated output current in parallel operation If le...

Отзывы: