Cortex COR-ACC995-V2 Скачать руководство пользователя страница 5

COR-ACC995-V2

V151027

   

H. Arming Password

J. Duress Code

K. Terminal Port

I. Arming Delay Time

Access programming mode

 →  

 

  

Parameters[1]

 →     

Arming PWD

 → 

Input 4-digit PIN (0001~9999; Default: 1234)

 → 

Succeeded

  

Or via 701Server and set it on ACC995-V2 screen

3

8

Or via 701Server to set it on ACC995-V2 screen

Duress Code is only available in networking mode. It will substitute a personal pin code and send the message of Duress to  computer as a    

    warning signal.

Access programming mode

 →  

 

  

Parameters[2]

 →     

Duress Code

 → 

4 sets (select one)

 → 

Input 4-digit PIN (0001~9999)

 → 

Succeeded

  

4

7

Access programming mode

 →  

 

  

Tools

 →     

Terminal Port

 → 

0:Lift ; 1:Host ; 2:LED ; 3:PRN (default value:1) 

→ 

Baud Selection 

(default value:9600)

 → 

Succeeded

  

5

4

L. Setting up the alarm / arming

Conditions:

1. Arming enabled
2.Alarm system connected

Application:
1. Door open too long

: Door is open longer than door relay time plus door close time.

2. Force open

 (Opened without a valid user card): Access by force or illegal procedure.

3. Door position abnormal

: When power is off and then on, reader on arming before power off.

Enable/Disable the arming status:

Standby Mode

Access Programming mode

Card only

Card or PIN

Card and PIN

Open the door
Present the tag to reader

 → 

Input 

4 digits arming PWD

 →

Input user address

 → 

Input 4 

digits individual PWD

 →      → 

Input 4 digits arming PWD

 →

Present the tag to reader

 → 

Input 

4 digits individual PWD

 →      → 

Input 4 digits arming PWD

 →

Enable:

 Access programming mode

 →     

Quit & Arming

7

Disable:

 Access programming mode

 →     

Quit

6

No open the door

     → 

Input 4 digits arming PWD

 

→ 

Present the tag to reader

Access programming mode

 →     

Parameters[1]

 →     

ArmingDelayTm

 → 

Enter armed sta. Delay time(Sec) ,Range:000~255

Armed pulse out-put time. (10ms) ,Range

000~255

 → 

Succeeded

  

3

7

※ 

[Use FP] can substitute for [Induct valid card].

F. Adding / Deleting Fingerprint or Finger-Vein

Adding

Access programming mode

 →  

 

  

User Setting

 →    

 Enroll FP

 → 

Key in 5-digit user address

 →

1 or 2 different fingers on the sensor lens 

→ 

Succeeded

P.S. The ACC995-V2 need to collect twice for each fingerprint.

2

6

Deleting

Access programming mode

 →  

 

  

User Setting

 →    

 Delete FP

 → 

Key in 5-digit user address

 → 

Succeeded

P.S. If you want to delete all users’ FP, key in 

99999

2

7

#

G. Access Mode

Access programming mode

 →  

 

  

User Setting

 

→     

Access Mode

 

→ 

Key in 5-digit user address (00000~08999)

 

→ 

0:Invalid; 1:Card; 2: Card or PIN; 3: Card and PIN

 

→ 

Finger Identify: 0: Must ; 1: Ignore

→ 

Succeeded

  

2

2

Access Mode

Finger Identify

Result

Hardware

701Client

Hardware

701Client

0:Invalid

0: Must

 

       Just fingerprint

       Just card control

 

Invalid User

1: Ignore

       Just fingerprint

       Just card control

1:Card

0: Must

       Just fingerprint

       Just card control

 

Card

1: Ignore

       Just fingerprint

       Just card control

 1. Card Only

 2. Finger Only

2:Card or PIN

0: Must

       Just fingerprint

       Just card control

 1. Card

 2. PIN

 3. Card+PIN

 4. Card+Card

 5. PIN+PIN

 6. PIN+Card

1: Ignore

       Just fingerprint

       Just card control

 1. Card Only

 2. PIN Only

 3. Finger Only

3:Card and PIN

0: Must

       Just fingerprint

       Just card control

 Card+PIN

1: Ignore

       Just fingerprint

       Just card control

 1. Card+PIN

 2. PIN

Содержание COR-ACC995-V2

Страница 1: ...igger Input Alarm Relay 6 Gray Transistor Output Max 12V 100mA Open Collector Active Low Power 7 Thick Red DC 12V 8 Thick Black DC 0V Cable P1 WireApplication Wire Color Description RS 485 for Lift Controller 1 Thick Green RS 485 B 2 Thick Blue RS 485 A Cable P4 WireApplication Wire Color Description 1 2 TCP IP Output 3 Orange White Net TX 4 Orange Net TX 5 Green White Net RX 6 Green Net RX 7 P3 C...

Страница 2: ...incorrect pin code or master code 4 Maximum error in ut of pin code and master code can be changed via the software 701Server default 5 times Power Green Alarm Red Alarm Green OK Green Error Red In processing Green Networking and interactively flash between the Month and DAY e g 12 07 12 07 Stand alone No flashing e g 12 07 Reference to picture Connect to Electric Bolt Wiring Diagram EXIT 1 2 3 4 ...

Страница 3: ...TE RTE RTE POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC Electric Strike Door Contact Strengthen security with ACC 899 If any fire emergency the people can escape by press a switch to open all doors Electric Bolt Electric Bolt Electric Bolt Fire Emergency Transistor IN4007 Transistor IN4007 Connect to Reader Magnet Lock Connect to Electric Strike Connect to Do...

Страница 4: ...ogramming mode 7 Access programming mode Add Delete Add RF Learn Input 5 digit user address Input Tag Units pcs Close Tag into RF Area If a batch of tags are Sequential input Tag Units pcs in the quantity of the tags and present the tag with the lowest number to the controller 1 2 Adding Tag by RF Learn Function Tag Information SITE CODE CARD CODE SITE CODE CARD CODE User capacity 16384 00000 1638...

Страница 5: ... Arming 7 Disable Access programming mode Quit 6 No open the door Input 4 digits arming PWD Present the tag to reader Access programming mode Parameters 1 ArmingDelayTm Enter armed sta Delay time Sec Range 000 255 Armed pulse out put time 10ms Range 000 255 Succeeded 3 7 Use FP can substitute for Induct valid card F Adding Deleting Fingerprint or Finger Vein Adding Access programming mode User Set...

Страница 6: ...git user address Input single floor number 1 64 2 4 Single floor Access programming mode User Setting Multi Floor Input 5 digit user address Select range 1 or 2 or 3 or 4 Input 16 digits multi floors number 0 disable 1 enable e g Set NO 114 can use it with the 8 F and 16F Access programming mode User Setting Multi Floor 114 1 0000000100000001 2 2 5 5 Multi floors Set Floor Stop 1 0 17 0 33 0 49 0 ...

Страница 7: ...y Tm 7 Arming Delay Tm 8 Arming PWD 2 User Setting 1 Password 2 Access Mode 3 Extend Options 4 Single Floor 5 Multi Floor 6 Enroll Finger 7 Delete Finger 1 Add Delete 1 Add Card ID 2 Add RF Learn 3 Suspend Address 4 Suspend ID 5 Delete Address 6 Delete ID 7 Recover Address 8 Recover ID 9 Antipass Group Reset all device parameters and user card data Access programming mode Parameters2 Factory Reset...

Страница 8: ...same as sticker on Ethernet Module device Please revise IP address you want and then click Update button After updating the IP please re connect the Web Browser by new IP address User Password The password composes of 10 characters at most it can be either A Z or 0 9 Change the log in password to lock the IP setting of Ethernet Module If the IP address of ACC995 V2 has changed We must enter the ne...

Отзывы: