Technical data

Servicejournal

Company: ................................................................

Installer: .................................................................. 

Installation date: ............................

Air volume during installation ................m3/          

Pressure ..............Pa

Date

Filter replacement 

Yes/No

Operation 

 

position 1-4

Pressure 

 

Pa

Operation meter 

 

hours

Signature

Connection: 230/50Hz
Connection output: 105 W

 

Weight: 21 kg
Size: W=440, H=225, D=410, D=575 mm incl. connectors

In the event of an operational stoppage contact:

Company: ...................................................................... ..........................Telephone................................................

Contact: ........................................................................ ..........................E-mail .....................................................

Содержание RS 400

Страница 1: ...Air volume m3 h free blowing 1 15 56 107 112 2 27 131 255 180 3 60 235 450 242 4 96 319 673 288 Potentiometer 1 2 3 4 Air volume m3 h at different pressures Pa Pa m3 h 680 655 630 605 580 555 530 505 480 455 430 405 380 355 330 300 275 250 225 200 175 150 125 100 75 50 25 0 305 280 255 230 205 180 155 130 105 80 55 Position 1 Position 2 Position 3 Position 4 ...

Страница 2: ...continuous operation Negative pressure ventilation of framed floors means that heated air from the living environment is drawn down into the floor The odorous air in the floor is extracted through a duct system that is connected to the fan unit The RS400 fan unit filter box and the duct system that extracts the odorous air are mounted in suitably heat ed areas of the house so they do not disturb t...

Страница 3: ... four positions Connector Ø 100 mm for extract air pressure side Mounting bracket for flexible installation Connector Ø 100 mm for supply air suction side Overheat protection RS 400 is equipped with overheat protection if the temperature in the fan motor becomes too high There is also rotation protection if the impeller should become locked Position RS400 in a heated area Accessory filter box Simp...

Страница 4: ...e during installation m3 Pressure Pa Date Filter replacement Yes No Operation position 1 4 Pressure Pa Operation meter hours Signature Connection 230 50Hz Connection output 105 W Weight 21 kg Size W 440 H 225 D 410 D 575 mm incl connectors In the event of an operational stoppage contact Company Telephone Contact E mail ...

Отзывы: