background image

RADIAL FAN

HP 2000XT 

USER MANUAL

Содержание HP 2000XT

Страница 1: ...RADIAL FAN HP 2000XT USER MANUAL ...

Страница 2: ...e of Contents User Manual HP 2000XT 3 Intended use 3 Manufacturing Directive 3 Safety information 4 Delivery inspection 5 Product Overview 5 Drying method Pressure drying 6 Accessories 7 Installation 7 Fault finding 7 Technical data 8 ...

Страница 3: ... assumes no responsibility or liability for damages or injuries caused by non compliance with the instructions herein use for other purposes than the intended or failure to observe its warnings Such as damage injuries or liabilities are not covered by the product warranty The product warranty does not cover consumables or normal wear and tear It is the responsibility of the buyer to inspect the pr...

Страница 4: ...jury 9 Install the fan steadily and leveled so that it cannot fall over 10 Keep children animals and spectators away from the work place while installation is undertaken 11 If the fan is broken if the power connector or the cable is damaged contact the retailer Do not repair the equipment if you have not received specific training by the manufacturer 12 Be careful not to damage the power cable The...

Страница 5: ...l fan HP 2000XT 1 pc Manual 1 pc Product Overview Below pictures present HP 2000XT with all its external features and controls Fan speed selector Air Outlets 6 x 50 mm 1 x 100 mm Foldable carrying handle Power switch on off Red switch Durable rubber feet Hour meter alt Time Kwh meter Air Inlet facing the floor ...

Страница 6: ... the dry air into the construction This way a pressure drying effect is achieved pushing the dry and warm air into the construction As this increases the vapour pressure difference it also increases the drying speed Note Pressure drying can cause release of fibers particles from the construction into the ambient air If that is a potential problem precautions such as sealing off the space with plas...

Страница 7: ... cable to a 1 phase 230 VAC socket with a 10A or maximum 16A fuse As the machine is normally used in humid or wet spaces the use of a ground fault circuit interrupter is strongly recommended 3 Put the power switch in position On and select fan speed high or low 4 Verify that the correct air flows are achieved Fault finding Symptom Probable cause Action Fan does not start Power cable not connected ...

Страница 8: ... Technical data HP 2000XT Typ LAF 50 LAF 50E LAF 50E2 LAF 100 LAF 100E LAF 150 LAF 150E Air volume m3 h High speed 1500 Low speed 500 Voltage 230 VAC 50 Hz Rated power W 295 Height x width x length mm 275 x 400 x 390 Weight kg 13 ...

Страница 9: ...nufactures sells and hires out high quality products for dealing with water damage moisture odours and radon We are market leaders and specialise in innovation within the industry Our products are compact effective ergo nomic and energy efficient In emergency situations and during flooding Corroventa s customers have access to one of the largest rental parks in Europe We have sales offices and mac...

Отзывы: