background image

EVOSHAKE 500 v2

10

 -

5

MACHINE INSTALLATION

5.1

General warnings 

Personnel in charge of these operations must wear the following personal 
protective equipment.  

 

5.2

Installation site requirements

The structural design of the EVOshake 500 v2 is geared towards it being functional and user-friendly. To ensure ease of 
use, take into account the following details when installing the machine:

1. The machine should be operated at room temperature (10 °C - 40 °C), in a room with no harmful humidity (relative 

humidity: 5% - 85%) or drafts and without condensation.

2. The machine must be placed in a clean and dust free place.

3. The room must be ventilated to prevent concentration of harmful fumes.

4. The operating site must have adequate lighting.

5. Place the mains plug in such a place that it can be unplugged without moving the machine.

6. Check that the floor is not slippery or uneven.

7. Reserve 40 cm free space above the machine, as the door opens upwards and needs space.

8. Electrical interface:

220 - 240 V ±5%
50 Hz / 6.3 A
Earthed wall socket. 

5.3

Unpacking and placement 

     

Tools required:

10 and 17 mm set wrench

One person is enough to carry out the following procedure.

The service representative will install the machine so that it is ready to be used. In addition, he will give training on how 
to use the machine.

1. Remove the carton box covering the machine.

2. Remove the cover from top of the EVOshake 500 v2.

3. Check that the EVOshake 500 v2 and accompanying equipment have not been damaged during transport.

4. Check that all the ordered items have been delivered, see the section “4.1 Contents of the basic package” on page 9.

DANGER

To avoid personal injuries and property damage, use the utmost care and caution when handling the machine, and 
carefully follow the instructions given in this chapter

WARNING

Only a service representative authorised by the supplier may install the machine.

WARNING

When using colorants containing volatile solvents the room in which the machine is installed must be spacious, 
with good ventilation (air exchange) and no type of parts must be leant against or stocked close to the machine.

For indoor use only!

dd

Make sure the packing has not suffered any damage or tampering during shipping; if so, contact the 
authorized technical service or your dealer.

Содержание EVOSHAKE 500 V2

Страница 1: ...EVOSHAKE 500 V2 Vibrational Shaker User manual V1 0 RC 10 2019...

Страница 2: ...mes data and addresses used in the screens and or examples are purely coincidental and serve as a reference only to clarify the use of the COROB products COROB has carefully reviewed the wording and i...

Страница 3: ...2 Handling 9 4 3 Product disposal and recycling 9 5 MACHINE INSTALLATION 10 5 1 General warnings 10 5 2 Installation site requirements 10 5 3 Unpacking and placement 10 5 4 Electrical connection and s...

Страница 4: ...ER Indicates a risk of personal injury WARNING Indicates a risk of damage to the machine that could interfere with its operation dd Indicates important instructions referring to precautionary rules an...

Страница 5: ...y automatic involving can clamping activations of the shaking motion unclamping of the can and opening the door 2 2 EVOshake 500 v2 s parts Table 1 Parts of the shaker The Emergency button is a safety...

Страница 6: ...nd address Marking Machine model Year of manufacture Serial number S N Electrical specifications Can handling features Type of cans Round square oval Max can diameter 370 mm Min height 50 mm Max heigh...

Страница 7: ...t Periodically check the condition of the mains cable if it is damaged replace it with a new cable supplied by the manufacturer Do not use extension cords to power the machine Do not use multisockets...

Страница 8: ...damages deriving from the non observance of this prohibition It is strictly forbidden to use the machine without protections or with any safety devices present on the machine disabled broken down or...

Страница 9: ...ng cans on the shelf may cause injuries Do not exceed the weight limits stated by the current regulations in force If necessary use appropriate lifting equipment ch 8 1 ch 6 5 Risk of falling objects...

Страница 10: ...PROG STOP 4 Label Place the can 5 Label Warning max can size 6 Label Electrical danger 7 Label Serial Number dd Do not remove or make illegible the safety or instruction labels Replace any label has...

Страница 11: ...the machine s operation and they can be removed after one year service life one year 4 3 Product disposal and recycling This equipment must not be disposed of with unsorted municipal waste Carry out...

Страница 12: ...cking and placement Tools required 10 and 17 mm set wrench One person is enough to carry out the following procedure The service representative will install the machine so that it is ready to be used...

Страница 13: ...hen the back leg reaches the ramp tilt more see figure 5 11 10 Carefully slide the shaker along the ramp cover to the floor see figure on the next page 11 Move the shaker to its working place bearing...

Страница 14: ...wheels 3 Adjust the four supporting feet to ensure that the shaker stands steadily 4 Make sure the shaker is levelled Shaker may be tilted backwards for 2 3 mm Figure 5 10 Get hold of the front of th...

Страница 15: ...essing PROG button 10 mm per push or STOP button 10 mm per push 13 Verify selection by pressing STOP button for 3 seconds stops blinking 14 Close menu by pressing PROG button for 3 seconds the display...

Страница 16: ...preset shaking programs DANGER Neglecting to follow safety instructions may lead to personal injury Read the safety instructions before operating the machine Never operate contrary to the instruction...

Страница 17: ...d on the door opens After shaking and unclamping the door opens automatically If the door is closed and you want to open it press STOP button Program Function Unclamp max Lifts the upper plate to max...

Страница 18: ...ing cycle execute the following steps 1 If the upper plate is too low raise it as follows Select declamp Close the door manually the machine declamps the upper plate to max open position the door open...

Страница 19: ...the door still does not open you can open it manually through the hole behind the shelf This hole is covered with a plug To open the door manually do the following 1 Press the emergency button 2 Remo...

Страница 20: ...the door the Cleaning starts and the machine runs cleaning cycle Display Cleaning Torque xx xx number that is changing When the Cleaning is finished the upper plate stops at Preferred height and the...

Страница 21: ...Set by can size Shaking direction Bi directional Type of cans Round square oval Max can diameter 370 mm Min height 50 mm Max height 410 mm Max can weight 40 kg Multiple can handling Yes Loading height...

Страница 22: ...ble for personal injury or property damage caused by improper use of the equipment or tampering with the guards and safety devices installed on the machine The following shall void the manufacturer s...

Страница 23: ...21 EVOSHAKE500v2 You will need the following information from the type shield See 2 4 Identifying information on page 4 when you call for service type MODEL serial number S N...

Страница 24: ...EVOSHAKE 500 v2 22 APPENDIX EC DECLARATION F A C S I M I L E...

Страница 25: ...23 EVOSHAKE500v2 F A C S I M I L E...

Страница 26: ...EVOSHAKE 500 v2 24...

Отзывы: