COROB EVOFLX-LW
-
22 -
7
USING THE DISPENSER
7.1
General warnings
Personnel in charge of these operations must wear the following personal
protective equipment.
7.2
At the beginning of the working day
At the beginning of each work shift, always carry out the following operations:
•
Check that the nozzle center is clean.
•
( With humidifier for solvent-based colorants or without humidifier) Check that the sponge is clean and saturated; if
it is necessary to saturate, use only appropriate liquid (the choice of the liquid depends on the nature of the
colorants, and must be done directly by the manufacturer of the products used).
•
( With humidifier for water-based colorants) Check that the water in the bottle is not below the minimum level.
•
Carry out system Purge (not necessary if the dispenser is equipped with Integrated Nozzle Valve System).
7.3
Running the machine
The operator is guided in running the machine by the management software, which displays the instructions to be
carried out and the actions performed by the machine
.
7.3.1
Loading the can - manual shelf
1.
Release the shelf by pulling the handle.
2.
Raise or lower the shelf, adjusting its height based on the size of the can to be used.
3.
Release the handle to lock the shelf in the desired position.
4.
Rotating cap
: Place the can on the shelf, push the opening bar and the cap opens.
Sliding cap
: Place the can on the shelf, making sure that photocell
A
is obscured
.
DANGER
The machine must be used by a single operator. Unauthorized people who could reach or touch machine parts
during operation must not be admitted in the nearby area.
It is strictly forbidden to use the machine without protections or with any safety devices present on the machine
disabled, broken down, or removed. The panels must be kept closed at all times.
Do not, for any reason, place your hands in the dispensing area when running the machine, except for loading and
unloading the cans.
When handling cans
,
do not exceed the weight limits stated by the current regulations in force.
Steps
Options
Ref.
Make the selections from the management software
(selection of the product, formula and can size).
with manual shelf
Load the can in the machine and adjust the height of the can
shelf.
with semiautomatic shelf
with automatic shelf
with roll conveyor
Adjust can position with respect to the dispensing center.
with can centering device
with Laser B.H.L.
Carry out punching of the can lid (optional).
with puncher
Via the software, enter the formula dispensing command.
When dispensing is finished, remove the can and proceed
with another dispensing process.
Содержание EVOFLX-LW
Страница 1: ...EVOFLX LW User manual V1 0 RB 2019...
Страница 30: ...COROB EVOFLX LW 28...
Страница 35: ...33 COROB EVOFLX LW...
Страница 36: ...COROB EVOFLX LW 34...
Страница 42: ...COROB EVOFLX LW 40 APPENDIX EC DECLARATION F A C S I M I L E...
Страница 43: ...41 COROB EVOFLX LW F A C S I M I L E...
Страница 44: ......
Страница 45: ......