4.4.2.4
RF Connections
The RF connections depend on the specific configuration add-ons (with / without RxU67, RxU2325, GEM).
Refer to the section relevant to your deployment:
•
For Installations that include RxU67 Add-on, 4.4.2.4.1
•
For Installations without RxU67, 4.4.2.4.2
•
For RAU5x Installations that include RxU2325, 4.4.2.4.3
•
For RAU5x Configurations that include GEMs, 4.4.2.4.4
4.4.2.4.1
For Installations that include RxU67 Add-on
Connect the cables between the RxU67 and the cavity Filter
1. Open the RxU67 cable kit
2. Select the cables with the appropriate length for your deployment (cavity on top /on side panels of RAU5x)
3. Connect the cables between the filter and RXU67/RAU according to their color and label
Figure 4-27. RAU5x with RxU67 - Cable Connections to filter
4.4.2.4.2
For Installations without RxU67
Connect optic fiber pair to RAU5x module LC APC optic connector. See Figure 4-28.
Figure 4-28. Ground, Fiber and RF Cable Connections for RAU5x