background image

Corning Optical Communications 

User Manual | Page 1 

 

GENERAL INFORMATION

 

PS-MP is a dual port digital transport platform supporting public safety coverage on fibre 
optic cable using the CPRI protocol. It adopts Feed-Forward Technology, allowing for 
deployment of legacy narrow band solutions while still benefiting from the digital 
transmission and filtering functionality. This platform is ideal for P25, DMR, PMR, 

GSM-R

 & 

Tetra technology either as standalone or complimentary with wideband cellular deployments. 

The PS-MP system supports programmable band or channel selective. The PS-MP supports 
up to 37 dBm output per ban. The PS-MP converts an optical signal to RF and then transmits 
at the relevant band and receives the analog RF signal, conditions it, and converts it back to 
optical for routing to the PS-AU. 

Medium-Power (PS-MP/PS-AU-AIR) 

User Programming Manual 

Public Safety

 

This document describes the User Manual for the PS-MP unit.

 

This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and 
QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC 
License to operate this device. NOTE: Only authorized person can enter the area where the 
antenna is installed. And the person is fully aware of the potential for exposure and can exercise 
control over his or her exposure by leaving the area or by some other appropriate means. 

Awareness of the potential for RF exposure in a workplace or similar environment can be provided 
through specific training as part of a RF safety program. 

Содержание PS-AU-AIR

Страница 1: ...nd then transmits at the relevant band and receives the analog RF signal conditions it and converts it back to optical for routing to the PS AU Medium Power PS MP PS AU AIR User Programming Manual Pub...

Страница 2: ...nspecting the Device 8 INSTALLATION PREPARATION 8 Site Investigation 8 Installation Tools 9 Torque Settings 9 Clearance 9 Grounding 9 4 INSTALLING THE ACCESS UNIT PS AU 10 ACCESSORIES LIST 10 RACK INS...

Страница 3: ...ommunications User Manual Page 3 PS MP MOUNTING DIMENSION SPACING 42 6 OPTICAL CONNECTION 43 OPTICAL TRANSCEIVER MODULE 43 Single Port Bidirectional SFP Transceiver 43 Dual Port SFP Transceiver 43 Opt...

Страница 4: ...LLERS You MUST have an FCC LICENSE or express consent of an FCC License to operate this device Unauthorized use may result in significant forfeiture penalties including penalties in excess of 100 000...

Страница 5: ...g The equipment has to operate at humidity level and temperature range as follow Maximum humidity 85 PS AU Operating Temperature range 10 C to 50 C PS MP Operating Temperature range 40 C to 50 C Stora...

Страница 6: ...Corning Optical Communications User Manual Page 6 For performance and safety reasons NEVER disassemble and remodel the devices...

Страница 7: ...ransportation carrier and notify them of the damage 3 File a claim with the carrier once you determine the extent of any damage 4 Return it to SUNWAVE s nearest RMA facility and contact SUNWAVE for RM...

Страница 8: ...e bar has not been damaged and the fittings and auxiliary parts are intact 7 Check that the silk screened images on the device are visible and intact Installation Preparation Site Investigation Before...

Страница 9: ...to the top of the rack FAN Cooling You can mount the fan between the bottom of the device and any other Maintain 2U clearance between the bottom of the device and any other Grounding Note Do not use...

Страница 10: ...Corning Optical Communications User Manual Page 10 4 Installing the Access Unit PS AU Accessories List...

Страница 11: ...k should safely support the combined weight of all the equipment and be securely anchored Installing the Access Unit in a climate controlled room with sufficient air circulation is recommended as the...

Страница 12: ...Corning Optical Communications User Manual Page 12 2 Recommended attaching the sliding rails to rack Not included in delivery...

Страница 13: ...Corning Optical Communications User Manual Page 13 3 Place the PS AU in the rack and secure the PS AU using 2 screws M6 16 on both sides and the Phillips screwdriver...

Страница 14: ...ed in the same rack It is necessary to allow at least 3 rack units 132mm of free space below each unit for heat dissipation without fan installed or 1 rack unit 44mm of free space below each unit with...

Страница 15: ...Corning Optical Communications User Manual Page 15 5 Connect and lock the power cable at the PS AU rear side 6 Connect and screw the ground wire at the PS AU rear side...

Страница 16: ...anual Page 16 Wall Installation To install the Access Unit on the wall 1 Rotate the handles 90 and attach them at the rear of the PS AU using 4 screws M3 6 per bracket and the Phillips screwdriver Obs...

Страница 17: ...l Page 17 2 Mark 4 x 6 8mm drilling holes sites for the hanger to be attached to the wall 3 Drill 4 holes at the marked sites using percussion drill and embed 4 10 plastic expansion pipes Note H 70mm...

Страница 18: ...Corning Optical Communications User Manual Page 18 4 Connect and lock the power cable at the PS AU rear side 5 Connect and screw the ground wire at the PS AU rear side...

Страница 19: ...Corning Optical Communications User Manual Page 19 PS AU Mounting Dimension Spacing...

Страница 20: ...al connections and route the cables from the signal source or CPOI to the Active Combiner module 2 Connect the cables from the signal source to the QMA female connectors on the Active Combiner module...

Страница 21: ...Corning Optical Communications User Manual Page 21 5 Installing the Remote Unit PS MP PS AU AIR Accessories Note PS AU AIR installation is same as PS MP installation...

Страница 22: ...User Manual Page 22 Wall Installation Back on the Wall 1 Attach and fasten the handle to the side of PS MP with screws M6 14 using T5 Wrench 2 Attach and fasten the Bracket I to the back of PS MP wit...

Страница 23: ...in the mounting Bracket II Note R 13mm 4 Drill 4 holes at the marked positions Note H 70mm 5 Attach the dowels expansion screws or the like and fasten the Bracket II to the wall Tips use Bracket II as...

Страница 24: ...Corning Optical Communications User Manual Page 24 6 Hang the PS MP on the mounting bracket II and fasten with nuts M10...

Страница 25: ...Corning Optical Communications User Manual Page 25 7 Fasten the Bracket I and II with screws M6 14...

Страница 26: ...Corning Optical Communications User Manual Page 26 8 Connect and lock the power cable 9 Connect and screw the ground cable...

Страница 27: ...Corning Optical Communications User Manual Page 27 10 Connect and tighten the waterproof network cable...

Страница 28: ...Corning Optical Communications User Manual Page 28 11 Connect and tighten the waterproof optical fibre...

Страница 29: ...Corning Optical Communications User Manual Page 29 Wall Installation Side on the Wall...

Страница 30: ...Communications User Manual Page 30 1 Attach and fasten the handle to the side of PS MP with screws M6 14 using T5 Wrench 2 Attach and fasten the Bracket I to the left side of PS MP with screws M6 14...

Страница 31: ...in the mounting Bracket II Note R 13mm 4 Drill 4 holes at the marked positions Note H 70mm 5 Attach the dowels expansion screws or the like and fasten the Bracket II to the wall Tips use Bracket II as...

Страница 32: ...Corning Optical Communications User Manual Page 32 6 Hang the PS MP on the mounting bracket II and fasten with nuts M10...

Страница 33: ...Corning Optical Communications User Manual Page 33 7 Fasten the Bracket I and II with screws M6 14...

Страница 34: ...Corning Optical Communications User Manual Page 34 8 Connect and lock the power cable 9 Connect and screw the ground cable...

Страница 35: ...Corning Optical Communications User Manual Page 35 PS MP PS AU AIR Wall Mounting Dimension Spacing...

Страница 36: ...PS MP 2 Install the bracket II and Bracket III to the pole 3 Hang the PS MP on the mounting bracket and fasten with nuts M10 4 Connect the ground cable and power cable Note The diameter of Pole shall...

Страница 37: ...Corning Optical Communications User Manual Page 37 Rack Installation...

Страница 38: ...Corning Optical Communications User Manual Page 38 1 Attach and fasten the Bracket III to the Standard 19 Rack with screws Note Please purchase Bracket III for rack installation separately...

Страница 39: ...al Communications User Manual Page 39 2 Attach and fasten the handle to the side of PS MP with screws M6 14 using T5 Wrench 3 Attach and fasten the Bracket I to the back of PS MP with screws M6 14 usi...

Страница 40: ...Corning Optical Communications User Manual Page 40 4 Hang the PS MP on the mounting bracket and fasten with nuts M10...

Страница 41: ...Corning Optical Communications User Manual Page 41 5 Connect the ground cable and power cable 6 Connect and screw the ground cable...

Страница 42: ...Corning Optical Communications User Manual Page 42 PS MP Mounting Dimension Spacing...

Страница 43: ...turns to green when optical modules are plugged in ports and synchronized When connection is down or there is no optical module in port the indicator remains red The single port SFP modules have to be...

Страница 44: ...on status of the upper and lower optical modules When a pair of optical modules are synchronized both uplink and downlink the indicators turn green as shown in the right pair of indicators in Figure b...

Страница 45: ...ant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This product generates uses and can radiate radio...

Страница 46: ...the right to improve enhance and modify the features and specifications of Corning Optical Communications products without prior notification A complete listing of the trademarks of Corning Optical C...