Quick Installation Sheet | CMA-600-AEN | Page 1

Corning Optical Communications

CMA-600-AEN

GX Higher Power 40 W      

Dual-Band WCS/2.5 GHz  

TDD DAS Remote 

Quick Installation Sheet

1. 

IMPORTANT!

 In the event the GX is:

 

•  Modified or altered by any party other than Corning; or 

 

•  Subjected to misuse or improper handling or installation;  

 

 Corning’s product warranty will be void and no longer valid. This includes replacing or removing connectors in  
the field during installation.

2.   In both indoor and outdoor applications, the GX unit should be mounted vertically with the connectors facing 

upwards/downwards. 

 

 IMPORTANT!

  If the GX is mounted horizontally in an indoor application, sufficient cooling must be ensured  

(i.e., air conditioning) and a sufficient tethering harness is required.

3.  

IMPORTANT!

 OptiTap® pull-out force ranges from a few lb to 50+ lb with the dust cap or connector installed.  

This prevents damages caused to the DAS unit.

4.   For deployments with the Corning® optical network evolution (ONE™) solution, the following additional elements 

are required (ordered separately):

 

•  Optical central hub (OCH-4-WDM/OCH-8-WDM) – performs the RF-to-optical conversion of the service signal

 

•  Interface box (IFB) – interfaces between the headend unit (HEU/IHU) and OCH

 

•  ERFCv2-OCH cable – extender cable interfacing to the RIX module and the OCH

 

•  SC-450 unit – system controller required for GX management

5.  Two people are required for mounting – unit weight: 147 lb (66.6 kg)

6.   Wooden pole-mountable option accessory kit (AK-GX-QUAD-BRKT-WDPOLE) is available (ordered separately). 

Instructions are provided with the kit. 

7.   For deployments alongside GX quad-band remotes – via the GX 2x1 external low-band and high-band combiner 

(P/N: AK-GX-LH-COMB).

GENERAL INFORMATION

This document describes the GX dual-band installation procedure. Note that a detailed description of the GX couplers and 

multiplexer are provided with the respective accessory kits.

Содержание ONE GX

Страница 1: ...p or connector installed This prevents damages caused to the DAS unit 4 For deployments with the Corning optical network evolution ONE solution the following additional elements are required ordered s...

Страница 2: ...emote Unit GX WCSM2500M 40 GX WCSM2500M 40 GX WCSS2500S 40 GX WCSS2500S 40 DC 1 Mounting Bracket used for both pole and wall mountable installations 1 Nuts M8 Spring Washers 8 Plain Washers 8 used for...

Страница 3: ...OCH CABLES includes four QMA QMA R A 1000 mm cables AK RIU 12 CABLES includes four RF QMA QMA R A 1000 mm cables 1 3 each IFB supports 12 QMA connections to OCHs OCH 4 WDM top 4 Port Optical Central H...

Страница 4: ...units Refer to Figure 1 for an example of where to install the units in the communication rack in order to facilitate the cable connections Step 1 Refer to Figure 2 and connect the 9 pin connector sid...

Страница 5: ...ry kits including appropriate cables can be ordered separately Each IFB supports connections to two optical modules i e one OCH 8 or two OCH 4 units per service group so that each unit supports connec...

Страница 6: ...de see Figure 6 measure and mark the location for drilling the supplied M10 masonry bolts 12 diameter in the wall six per bracket Step 2 Drill holes for the masonry bolts using an electric drill with...

Страница 7: ...xternal combiner AK GX LH COMB quick installation sheet for detailed installation procedure instructions The GX low band and high band external combiner interfaces to the GX dual band and to the GX 4x...

Страница 8: ...s will damage GX internal power amplifier after the equipment is powered on Make sure all connections are performed correctly before powering For direct connections to DAS antennas Step 1 Using the re...

Страница 9: ...e connected to a different optical module as shown in Figure 13 Step 1 Install splice box near the remote unit Step 2 Referring to Figure 13 connect OptiTap cable to splice box and to the GX OP OptiTa...

Страница 10: ...ws See Figure 15 Step 2 Referring to Figure 16 remove retaining nuts and route power cord through provided tubing gaskets noting the following Tubing gasket is required for power cord diameter in rang...

Страница 11: ...rify normal operation via LEDs Figure 19 External Alarm Pinout Description LED Status Description RUN Blinking green Normal status power on Off Alarm status COMM Steady red General alarm Blinking red...

Страница 12: ...features and specifications of Corning Optical Communications products without prior notification A complete listing of the trademarks of Corning Optical Communications is available at www corning co...

Отзывы: