STANDARD RECOMMENDED PROCEDURE 203-297 | ISSUE 2 | MAy 2015 | PAGE 4 OF 4

Corning Optical Communications LLC • PO Box 489 • Hickory, NC 28603-0489 USA 

800-743-2675 • FAX: 828-325-5060 • International: +1-828-901-5000 • www.corning.com/opcomm

Corning Optical Communications reserves the right to improve, enhance, and modify the features and specifications of Corning Optical Communications products 

without prior notification. A complete listing of the trademarks of Corning Optical Communications is available at www.corning.com/opcomm/trademarks. All other 

trademarks are the properties of their respective owners. Corning Optical Communications is ISO 9001 certified. © 2009, 2015 Corning Optical Communications. 

All rights reserved.

8. 

Upgrade Line Count

To add additional lines, remove the plastic divider and install 

modules in next available position as required. Replace remaining 

plastic divider segments in any unused positions.

With the module at 45 degrees and mounting feet aligned with 

openings in base (Figure 8), press feet into openings and rotate 

telco terminal end of the module onto the ground bar tang until 

ground clip is fully engaged.

9. 

Testing

9.1  Continuity of the Telco Wiring

Step 1: 

With the stuffer in the down position, insert test clips into the center of the 

test holes on top of the protector in the orientation shown (Figure 9).

Step 2: 

Test per standard company practices.

9.2  Continuity of the Subscriber Wiring

Step 1: 

Open the line module door by sliding the orange latch to the right. Insert 

test clips into the test ports on the subscriber line module in the orientation 

shown for each test to check continuity of the entire line module or to 

check each line (Figure 10). Move the orange levers to the connected and 

disconnected positions to check each individual line.

Step 2: 

Test per standard company practices.

Step 3: 

Slide the orange module latch all the way to the left and close the module 

door.

Figure 10 

KPA-2324

Press Down

Ground 

Bar

Insert foot of adapter 

into opening in NID.

Figure 8k 

KPA-2329

Figure 9 

CUSTOMER

NETWORK

KPA-2328

Test Subscriber/Customer continuity to 

each subscriber line inside the premises 

with test clips in this position.

Toggle the orange lever for each 

separate line.

Test Telco/Network continuity 

from line module to protector with 

test clips in this position.