background image

                                                                                                                                                                                               Tec hni c al  Ins truc ti ons

                                                                                            Oc t ober 19, 2007

C o r n i n g   C a b l e   S y s t e m s   G m b H   &   C o .   K G   ·   L e i p z i g e r   S t r .   1 2 1   ·   1 0 1 1 7   B e r l i n ,   G e r ma n y
T E L :   0 0 8 0 0 - 2 6 7 6 - 4 6 4 1   ( 0 0 8 0 0 - C O R N I N G 1 )   ·   F A X :   + 4 9 - 3 0 - 5 3 0 3 - 2 3 3 5   ·   E m a i l :   e me a . c s @ c o r n i n g . c o m
w w w . c o r n i n g . c o m/ c a b l e s y s t e ms

Corning Cable Systems reserves the right to improve, enhance and modify the features and specifications of Corning Cable Systems’ 

products without prior notification. LANscape

is a registered trademark of Corning Cable Systems Brands, Inc. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO 9001 certified. ©
2007 Corning Cable Systems. All rights reserved. Published in the EU.

Maintaining the Pretium Tool

Problem: Power light does not come on or flashes

Possible Cause:

Solution:

1.  The battery is low and needs to be

replaced

à

1.  Replace the battery. If the light is still flashing

or not shining, please place an RMA

Problem: Cannot get a green light

Possible Cause:

Solution:

1.  Cover not closed

à

2.  Error Light not cleared

à

3.  Fibre not inserted correctly in the

connector.

à

4.  Bad Cleave

à

5.  Broke fibre in the connector or defective

connector

à

6.  Weak Batteries

à

1.  Close lid before inserting the field fibre.

2.  Check problem point “Power light does not

come on or flashes”

3.  Hit reset button and repeat inserting field
      Fibre in the connector and re- Cam.

4.  Check chapter “Maintaining the Pretium

FBC-015 Cleaver”

5.  Remove the connector and place another
      one in the tool and retry

6.  Replace batteries

If these maintaining instructions did not help solving the problem, please place a RMA

”Cam”-
Button

         ”Reset”-

„Reset“-
Button