User Manual v1.0
Corning Restricted and Confidential Proprietary - Controlled content
UM - Everon 6000 DAS - 19-DEC-2020.docx| December 2020
|Page 52 of 170
2.3.3
Mount chassis in 19-in Rack
Note: for dimensions and specifications refer to chapter 7
1.
Before mounting the chassis: unwrap each of the PAMs, and enter each PAM to its dedicated slot inside
the chassis, according to the color-codes:
2.
Determine the location of the MRU in the rack while considering additional units (e.g. power supply)
3.
Referring to Figure 4
secure the units’ rack ears to the rack frame as follows
:
a.
Insert two screws halfway into the rack frame (one on each side)
b.
Position the bottom half slots of the chassis rack ears onto the screws
c.
Secure the unit in the rack via remaining applicable bracket holes using the appropriate rack
nuts and screws
Figure 4. Example of MRU Chassis Rack Installation