6
7
SPECIFICATIONS
MODEL NO.
CIC-ES2008
RATED VOLTAGE / FREQUENCY
220-240V~ 50/60Hz
RATED WATTAGE
2000 W
TROUBLESHOOTING
OPERATING INSTRUCTIONS
After the device has been turned on, select the appropriate function according to cooking preference
by using the function selector button. Press the Function button and the LED light will light up to show
the selected function.
CLEANING AND CARE
1. Disconnect the power plug and wait until the device is cooled down completely. Clean after using
it every time.
2. If pots/pans are used without being cleaned, discoloration or cooking stain may appear.
3. Do not use benzene, thinner, scrubbing brush or polishing powder to clean the Induction Cooker.
4. Wipe using a damp cloth with dish washing agent.
5. To remove dirt from the air intake and exhaust vent, use a vacuum cleaner to extract it.
6. Never clean the device over running water. The Induction Cooker is not waterproof and water that
gets inside may cause malfunction.
Note: After finished cooking, turn off the device but do not turn off and remove the power plug
yet. Its fan will be running to cool down the device. Remove only when the fan stops.
Function Type
Function
Default
Adjustable
Preset Timer
Timer
Temperature
Temperature
Range
Manual
280°C
10 levels:
–
4 hours
60°C to 280°C
1400W
10 levels:
–
4 hours
120W to 2000W
Automatic
300W
–
24 hours
–
1600W
–
24 hours
–
2000W
–
24 hours
–
ERROR
POSSIBLE CAUSES
SOLUTION
CODE
E1
Plate surface temperature sensor
Contact the supplier or send it to an authorized service center.
malfunction.
E2
IGBT temperature sensor malfunction.
Contact the supplier or send it to an authorized service center.
E3
Abnormal power voltage. Voltage too high.
Check power supply. Power on after power supply is back to normal.
E4
Abnormal power voltage. Voltage too low.
Check power supply. Power on after power supply is back to normal.
E5
Plate surface temperature sensor
Wait for a few minutes until the device cools down and check pot/pan.
short-circuited because empty pot/pan
is used.
E6
Fan failure. Air intake/exhaust vent blocked.
Contact the supplier or send it to an authorized service center. Clean the
vent after the device cools down. Restart.
E7
Coil panel is not well connected.
Contact the supplier or send it to an authorized service center.
Circuit malfunction.
E8
No or non-usable pot/pan on the cooktop.
Use suitable cooking pot/pan on the cooktop.
Содержание CIC-ES2008