Viper Low overrun Service Manual
© 2016, Cornelius Inc
- 27 -
Publication Number: 621360241LOEWSE
Figure 22. Manual Diagnostic Screen
The items shown in Table 25 are for the first barrel in the unit only. The list includes additional components with
their related barrel number, i.e. Hot Gas Sol #2, etc.
!
CAUTION:
The compressor can suffer damage if it is allowed to run without either a hot gas defrost or liquid line solenoid
open. The software is designed to turn on the hot gas solenoid for a barrel to prevent damage from occurring.
To move between one set of barrel parameters to the next, press the Right or Left arrow keys. This moves the high-
light to the first entry of the second barrel, etc.
Totals Menu
The Totals menu (Figure 23) shows the cumulative run time of the system, a component of the system or an error.
Some individual items may be reset, where available, by highlighting the item and pressing the RESET button. The
RESET button is only displayed for items that may be reset, such as hours since the motor seal was changed or the
number of compressor cycles. Pressing the BACK button returns to the Choose menu and saves the changes. The
description of each item in the Totals list is shown in Table 26.
To move between one set of barrel parameters and the next, press the Right or Left arrow keys. This highlights the
first entry of the second barrel, etc.
Table 25.
Display
Description
POS LIGHTING
This selection turns the Point-Of-Sale lighting on and off
COMPRESSOR #1
This selection turns the compressor on and off
HOT GAS SOL #1
This selection opens and closes the hot gas solenoid for barrel 1
PRODUCT SOL #1
This selection opens and closes the product solenoids and
valves for barrel 1
CO2 VALVE #1
This selection opens and closes the CO
2
solenoid and valve for
barrel 1
LLS VALVE #1
This selection opens and closes the Liquid Line solenoid and
valve for barrel 1
BRL MOTOR #1
This selection turns the barrel 1 motor on and off
MANUAL
DIAG
12:51P
MAR 04
POS LIGHTING OFF
COMPRESSOR #1 OFF
BACK ON OFF
HOT GAS SOL #1 ON
PRODUCT SOL #1 OFF
CO2 VALVE #1 OFF
LLS VALVE #1 OFF