Viper Service Manual
Publication Number: 621260373SER
- 58 -
© 2008-2016, Cornelius Inc.
Figure 48. Front view of CO
2
Regulators w/ Access Panel Removed (2 Barrel Unit)
C
ONDENSER
F
AN
M
OTOR
R
EPLACEMENT
The fan motor is located on the top of the unit, as shown in Figure 49. If the motor needs replacement, perform
the procedure in Table 52. to remove and reinstall a motor.
Locking
Nuts
Locking
Nuts
Figure 49. Condenser Fan Mounting Nuts
Table 51.
Step
Action
1
Disconnect power from the unit.
2
Remove the access panel (two (2) screws) and the right side panel.
3
Turn off the CO
2
source and then turn the Product valve 90 degrees to the off position.
4
Relieve pressure in the barrel by opening the relief valve on the faceplate of both barrels.
5
Disconnect the three (3) supply lines at the rear of the regulators using a small wrench.
6
Remove the two lock nuts from the mounting bracket in back of the regulators.
7
Remove the pressure switch wires from the regulators.
8
Remove the assembly and replace the defective regulator.
9
Reverse the procedure to install the regulator assembly.
10
Check the system for leaks after repressurizing the system.
11
Reset the regulator to the desired setting.
CO2 Regulators
Barrel 1
Barrel 2