background image

November 30, 1984

189159001

Revised: December 10, 1991

E

IMI Cornelius Inc; 1984-91

IMI CORNELIUS INC.
One Cornelius Place

Anoka. MN 55303-6234
Telephone (800) 238–3600
Facsimile (612) 422–3246

COPPER EVAPORATOR COIL KIT (P/N 185216000)

ON

UNIVERSAL 750 PRE-MIX DISPENSER

IMPORTANT: Only qualified Personnel should install this Kit.

INTRODUCTION

The purpose of this kit is to replace the original expanded aluminum evaporator, which also doubles as the wa-
ter bath tank, with a new copper tube style evaporator. The old aluminum evaporator remains in place as the
water bath tank only.

A new anode and refrigeration system dual inlet strainer/dryer are also included with the kit and must be instal-
led.

Retain these instructions as part of your equipment manual.

UNPACKING THE KIT

Unpack and inspect the kit. Make sure Loose-Shipped Parts are present and in good condition (see Figure 1).

Table 1. Loose-Shipped Parts

Item

No.

Part No.

Name

Qty.

1

319238088

Suction Line Ass’y

1

2

186843000

Anode

1

3

187969000

Sheet Metal Screw, Phil Pan Hd, Type ‘‘A’’ Alum; No. 10 by 1/2-in.

1

4

185215000

Copper Evaporator Coil

1

5

319225000

Coil Spacer

4

6

320389000

Thread Rolling Screw, Phil Pan Hd, No. 6-32 by 1/4-in.

4

7

960050

Rubatex Insulation, 6-ft. long

1

8

2601

Strainer Dryer, Dual Inlet

1

9

189159001

Instructions

1

REQUIRED SUPPLIES AND EQUIPMENT

Supplies required are as follows:

Brazing alloy ‘‘Phos-Copper’’, ‘‘Silfos’’ or equivalent is required for copper-to-copper connections. These alloys
contain about 15% silver.

Brazing alloy. ‘‘Easy-flow’’ or equivalent is required for copper-to-steel connections. This alloy contains about
50% silver.

Содержание Universal 750 Pre-Mix

Страница 1: ...hese instructions as part of your equipment manual UNPACKING THE KIT Unpack and inspect the kit Make sure Loose Shipped Parts are present and in good condition see Figure 1 Table 1 Loose Shipped Parts...

Страница 2: ...eter 0 300 VAC To measure line voltage 9 Ohmmeter 0 10 and 100 000 ohms To check resis tance of electrical circuitry 10 Leak detector capable of detecting at least 1 2 ounce year To detect refriger an...

Страница 3: ...nd lay them off to one side 7 Unit with sealed evaporator tank A Very carefully lift product coil basket up out of evaporator tank and lay them off to one side IMPORTANT If evaporator tank has hole in...

Страница 4: ...ATOR TANK ONLY COVER RETAINING SCREW 8 CUT OUT WITH HACK SAW PLATE GASKET SUCTION LINE ASSEMBLY ITEM 1 INSTALLATION POSITION SCREW 4 ITEM 6 SIDE PANEL RETAINING SCREW 4 ACCESS GRILLE RETAINING SCREW 4...

Страница 5: ...ide lower part of unit Pinch off or plug tubes 5 Remove old suction line assembly including accumulator and old dual inlet strainer dryer from inside unit 6 Very carefully see Figure 1 bend SUCTION LI...

Страница 6: ...ation system with 10 ounces of clean dry R 12 refrigerant ASSEMBLY 1 Push corner of unit side and front panel together 2 Install THREAD ROLLING SCREWS item 6 in first four holes top to bottom to secur...

Страница 7: ...hex nuts L Connect agitator motor ground wire and power cord M Connect product inlet line swivel nut connectors to product coil line fittings on cover assembly IMPORTANT Install RUBATEX INSULATION it...

Страница 8: ......