6
620917311
INSTALLATION INSTRUCTIONS
IMPORTANT: It is the responsibility of the installer to ensure that the drains from the dispensing
equipment is installed and maintained according to Federal, State and Local Laws.
1. Locate the dispenser indoors on a level counter top.
A.
COUNTER MOUNTING
The ice dispenser must be sealed to the counter. The template drawing indicates the opening that must
be cut in the counter. Locate the desired position for the dispenser, then mark the outline dimensions on
the counter using the template drawings. Cut openings in counter.
Apply a continuous bead of NSF International (NSF) listed silastic sealant (Dow 732 or equal) approxi-
mately 1/4” inside of the unit outline dimensions and around all openings. Then, position the unit on the
counter within the outline dimensions. All excess sealant must be wiped away immediately.
2. The drain tube is routed through the large opening in the bottom of the unit. See the MOUNTING TEMPLATE
(page 5) for locating the required clearance hole in the counter for these utility lines. The power cord is
routed through the holes in the side of the unit.
3. SINK DRAIN ASSEMBLY: Connect the drain tube to an open drain. Additional drain tubing is provided with
the unit. The drain tube must continuously pitch downward and contain no “traps” or improper drainage will
result.
A.
Use 3/4
I
nominal plastic pipe.
B.
To assure proper drainage, do not allow “trap” to form in drain line. Be sure drain line runs flat with bot-
tom of dispenser.
NOTE: This equipment must be installed with adequate backflow protection to comply with federal, state,
and local codes.
4. Clean the hopper interior (see CLEANING INSTRUCTIONS in Operator’s Manual).
5. Connect the power cord to a 120 volt, 60 cycle, 15-Amp, 3-wire grounded receptacle.