Cornelius UC 150 Скачать руководство пользователя страница 6

UC150 Ice Dispenser Installation Manual                              

Publication Number: 620917312

- 2 -

© 1999-2010, IMI Cornelius Inc.

S

AFETY

 P

RECAUTIONS

This unit has been specifically designed to provide protection against personal injury. To ensure continued protection 
observe the following:

!

WARNING:

Disconnect power to the unit before servicing following all lock out/tag out procedures established by the user. Verify 
all of the power is off to the unit before any work is performed.

Failure to disconnect the power could result in serious injury, death or equipment damage.

CAUTION:

!

Always be sure to keep area around the unit clean and free of clutter. Failure to keep this area clean may result in 
injury or equipment damage.

S

HIPPING

 A

ND

 S

TORAGE

CAUTION:

!

Before shipping, storing, or relocating the unit, the unit must be sanitized and all sanitizing solution must be drained 
from the system. A freezing ambient environment will cause residual sanitizing solution or water remaining inside the 
unit to freeze resulting in damage to internal components.

CO

2

 (C

ARBON

 D

IOXIDE

) W

ARNING

!

DANGER:

CO

2

 displaces oxygen. Strict attention MUST be observed in the prevention of CO

2

 gas leaks in the entire CO

2

 and 

soft drink system. If a CO

2

 gas leak is suspected, particularly in a small area, IMMEDIATELY ventilate the 

contaminated area before attempting to repair the leak. Personnel exposed to high concentrations of CO

2

 gas 

experience tremors which are followed rapidly by loss of consciousness and DEATH.

M

OUNTING

 

IN

 

OR

 

ON

 

A

 C

OUNTER

!

WARNING:

When installing the unit in or on a counter top, the counter must be able to support a weight in excess of 350 lbs.

 

to 

insure adequate support for the unit. FAILURE TO COMPLY COULD RESULT IN SERIOUS INJURY, DEATH OR 
EQUIPMENT DAMAGE.

NOTE: Many units incorporate the use of additional equipment such as ice makers. When any addition 

equipment is used you must check with the equipment manufacturer to determine the 
additional weight the counter will need to support to ensure a safe installation.

Содержание UC 150

Страница 1: ...ICE DISPENSER Installation Manual Revision Date August 1999 Publication Number 620917312 Revision Date August 3 2010 Revision C Visit the IMI Cornelius web site at www cornelius com for all your Lite...

Страница 2: ...rvice required by or loss or damage resulting from any of the following occurrences including but not limited to 1 other than normal and proper use and normal service conditions with respect to the Pr...

Страница 3: ...ety Overview 1 Recognition 1 Different Types of Alerts 1 Safety Tips 1 Qualified Service Personnel 1 Safety Precautions 2 Shipping And Storage 2 CO2 Carbon Dioxide Warning 2 Mounting in or on a Counte...

Страница 4: ......

Страница 5: ...moderate injury or equipment damage SAFETY TIPS Carefullyreadandfollowall safety messages inthismanualandsafety signsontheunit Keepsafety signsin goodconditionandreplace missingordamageditems Learnho...

Страница 6: ...l cause residual sanitizing solution or water remaining inside the unit to freeze resulting in damage to internal components CO2 CARBON DIOXIDE WARNING DANGER CO2 displaces oxygen Strict attention MUS...

Страница 7: ...be manually filled with ice this dispenser will dispense cubes up to 1 1 4 in size cube lets and hard chipped or cracked ice SPECIFICATIONS CORIAN IS CUT FROM COUNTER AND IS REWORKED AS SHOWN ABOVE B...

Страница 8: ...2010 IMI Cornelius Inc THE ABOVE FIGURE SHOWS THE REQUIRED CUTOUT FOR PLACING THE ICE DISPENSERINTO A COUNTER TOP THE DOTTED LINE IS THE ACTUAL CUTOUT DIMENSIONS WHILE THE SOLID LINE SHOWS THE AMOUNT...

Страница 9: ...Amp 3 wire grounded receptacle 3 The drain tubes are routed through the large opening in the bottom of the unit The power cord is routed through the holes in either side of the unit A Use 3 4 nominal...

Страница 10: ...UC150 Ice Dispenser Installation Manual Publication Number 620917312 6 1999 2010 IMI Cornelius Inc Figure 3 Torsion Bar Removal...

Страница 11: ...UC 150 Ice Dispenser Installation Manual 1999 2010 IMI Cornelius Inc 7 Publication Number 620917312 Figure 4 Wiring Diagram...

Страница 12: ...UC150 Ice Dispenser Installation Manual Publication Number 620917312 8 1999 2010 IMI Cornelius Inc Figure 5 Agitator Motor and Dispense Switch Wiring Detail...

Страница 13: ...UC 150 Ice Dispenser Installation Manual 1999 2010 IMI Cornelius Inc 9 Publication Number 620917312 Figure 6 UC 150 Plumbing...

Страница 14: ...UC150 Ice Dispenser Installation Manual Publication Number 620917312 10 1999 2010 IMI Cornelius Inc...

Страница 15: ......

Страница 16: ...IMI Cornelius Inc www cornelius com...

Отзывы: