INSTALLATION

This section describes receiving, unpacking,
selecting location, and installation of the Unit.

RECEIVING

Each Unit is completely tested under operating
conditions and thoroughly inspected before
shipment. At time of shipment, the carrier accepts
the Unit and any claim for damage in transit must be
made with the carrier. Upon receiving Unit from the
delivering carrier, carefully inspect the carton for
visible indication of damage. Any damage or
irregularities should be noted at time of delivery (or
not later than 15 days from date of delivery) and
immediately reported to the delivering carrier.
Request a written inspection report from the Claims
Inspector to substantiate claim. File claim with the
delivering carrier, not with IMI Cornelius Inc.

UNPACKING AND INSPECTION

Unpack Unit as follows:

1. Carefully remove packaging material.

2. Retain Service Manual and loose-shipped parts.

3. Inspect all parts of the Unit for evidence of

damage. If such evidence is found, file a claim
against the carrier.

4. Remove loose-shipped parts from poly bags

and check their identity and quantity against
Table 2.

Table 2. Loose-Shipped Parts

Item

No.

Part No.

Name

Qty

41-6401

Unit

Qty

41-6402

Unit

1

397180-039

Cup Rest

1

2

397179-039

Drip Tray

1

3

178025-100

Tapered Plastic

Gasket

2

2

4

770716-020

Adapter Fitting,
7/16-20 Female by
5/8-18 Male

1

1

5

312071-000

Decal Kit

1

1

6

312020–000

Service Manual

1

1

7

312971-000

Mounting Screws

2

2

8

300098-000

Hole Plugs

2

2

9

151707

Screw, Thd Rolling,
8–32 By 3/8 in. long

2

2

IDENTIFICATION OF LOOSE-SHIPPED
PARTS

1. CUP REST (item 1) fits inside DRIP TRAY (item

2).

2. DRIP TRAY (item 2) supports cup rest and

receives product spillage.

3. TAPERED PLASTIC GASKETS (item 3) seal

water and concentrate connections at rear of
Unit.

4. ADAPTER FITTING (item 4) connects 3/8 in.

O.D. plain water source line to the Unit.

5. DECAL KIT (item 5). Decals for product

identification on the Unit and front of dispensing
valve – Instructions for applying decals included.

6. SERVICE MANUAL (item 6). A guide to

installation, operation, and maintenance of the
Unit.

7. MOUNTING SCREWS (item 7) for mounting

Unit Base to counter, if desired.

8. HOLE PLUGS (item 8) to close inlet openings in

back of Unit if inlet lines are routed down
through counter top.

9. SCREW (item 9) to secure cover on top of the

Unit.

SELECTING LOCATION

This Unit may be island-mounted or installed on a
front or rear countertop provided that the following
requirements are satisfied. Unit may be fastened to
countertop using screws through Unit Base.

1. Locate Unit near a source of cold (100

°

F max)

plain water having a pressure of 40 to 125 psig.

2. Locate Unit to minimize length of concentrate

line.

To comply with National Sanitation Foundation (NSF)
requirements within the United States, Unit base
must be sealed to countertop when screws are used
to fasten Unit Base to countertop. Proceed as follows
to seal base to countertop.

1. Tilt up to expose bottom of base.

2. Liberally apply silastic sealant (such as Dow

Corning RTV 731 or equivalent) on base bottom
edges.

Note: Do not move Unit after positioning or seal
from base to countertop will  be broken.

Содержание TEA URN

Страница 1: ...ectly connected to a potable water supply shall be sized installed and maintained according to Federal State and Local laws Printed in U S A 94 IMI CORNELIUS INC 1993 94 IMI CORNELIUS INC One Corneliu...

Страница 2: ...OX CONCENTRATE SYSTEMS 9 CLEANING THE NITROGEN GAS CHECK VALVE 9 PAGE TROUBLESHOOTING 13 WATER TO CONCENTRATE RATIO OF DIS PENSED PRODUCT TOO LOW OR TOO HIGH 13 ADJUSTMENT OF DISPENSING VALVE CON CENT...

Страница 3: ...approximate Shipping 11 pounds Dry Weight 8 pounds Dispensing Rate approx 1 1 2 ounces sec Ambient Operating Temperature 40_F to 100_F Operating Pressures Water Inlet Supply Line 40 to 125 psig FIGUR...

Страница 4: ...DIOXIDE CO2 GAS CYLINDER ADJUSTABLE CONCENTRATE FLOW REGULATOR ADJUSTABLE WATER FLOW REGULATOR SHUTOFF VALVE LINE LEGEND WATER CONCENTRATE GAS DISPENSER BAG IN BOX CONCENTRATE CONTAINER CONCENTRATE P...

Страница 5: ...Hole Plugs 2 2 9 151707 Screw Thd Rolling 8 32 By 3 8 in long 2 2 IDENTIFICATION OF LOOSE SHIPPED PARTS 1 CUP REST item 1 fits inside DRIP TRAY item 2 2 DRIP TRAY item 2 supports cup rest and receives...

Страница 6: ...TS item 3 2 Connect other end of concentrate source line connected to the Unit to outlet fitting on bag in box concentrate pump 3 Connect concentrate source line from bag in box location to inlet fitt...

Страница 7: ...To syrup Ratio of dispensed product should be checked periodically and adjusted if necessary Refer to SERVICE AND MAINTENANCE section of this manual for adjustment procedure ADJUSTING PRIMARY CO2 REG...

Страница 8: ...ECK VALVES The CO2 gas check valve must be inspected and serviced as instructed at least once a year under normal conditions and after any CO2 system servicing or disruption Servicing of CO2 gas check...

Страница 9: ...the amount of water was too much turn dispensing valve water flow regulator adjusting screw Figure 3 counterclockwise a quarter of a turn at a time Repeat dispensed water measurement after each adjust...

Страница 10: ...leaning instructions is to remove only external residue from the valve and it s baffle and nozzle 1 Remove acorn nut securing dispensing valve cover then remove cover 2 Remove nozzle and baffle assemb...

Страница 11: ...n the entire CO2 and soft drink system If a CO2 gas leak is suspected particularly in a small area immediately ventilate the contaminated area before attempting to repair the leak Personnel exposed to...

Страница 12: ...G CO2 SYSTEM CO2 GAS CHECK VALVES see Figures 2 and 4 The primary CO2 regulator CO2 gas check valve must be inspected and serviced at least once a year under normal conditions and after any servicing...

Страница 13: ...mp A Adjust primary CO2 regulator or check CO2 supply and replenish as instructed B No concentrate supply B Replenish concentrate supply as instructed C Quick disconnect not secure on bag in box conta...

Страница 14: ...d E Adjust Water to Concentrate Ratio of dispensed product as instructed F No CO2 gas supply F Replenish CO2 gas supply as instructed G Dispensing valve concentrate flow regulator bag in box quick dis...

Страница 15: ...TER D WARWICKSHIRE B49 6 EU ENGLAND D 44 789 763 101 D FAX 44 789 763 644 FRANCE D 71 ROUTE DE ST DENIS D F 95170 DEUIL LA BARRE D PARIS FRANCE D 33 1 34 28 6200 D FAX 33 1 34 28 6201 GERMANY D CARL L...

Страница 16: ...ag in box hookup This revised manual was never released on a PCN Talked to George Murphy about this 08 11 94 and he said not to be in a hurry to release the revised manual as they have a rather large...

Отзывы: