Signature Service Manual
© 2011, IMI Cornelius Inc.
- 13 -
Publication Number: 621058426SER
Draining the Unit
Table 5.
Step
Procedure
1
Press ON/OFF
Button to turn off the unit.
NOTE: It is recommended that you shut the unit off as far ahead of
cleaning as possible to allow the product in the barrel to
thaw for easier removal.
2
NOTE: Air tube and blade sweepers are only used for dairy products.
Remove the Bowl Lid Cover and Air Tube. Place the Air Tube in a parts bin to be
cleaned later. Replace the Bowl Lid Cover. See Figure 3.
3
Press the ON/OFF
Button to turn the unit ON and push the CLEAN
Button.
4
Place an empty bucket under the Product Dispense Valve and move dispense
handle to the right (open position, shown in Figure 4) and drain as much liquid
as possible. Allow the last of the product to drain, then close the dispenser
valve by turning the dispense handle all the way to the left.
Press ON/OFF
Button to turn OFF the unit.
5
NOTE: Skip this step if the unit does not have the 2 for 1 feature.
Place the bucket under the 2 for 1 Dispense Nozzle, pull the handle and
allow the product to drain until the line is empty, see Figure 5.
Figure 5.
Figure 4.
22 ffoorr 11 DDiissppeennssee
NNoozzzzllee
DDiissppeennssiinngg
VVaallvvee
Figure 3.
Содержание signature
Страница 53: ......
Страница 54: ...IMI Cornelius Inc www cornelius com...