Number of Wires  .  .  .  .  .  .  .  .  .  .  . 3
max . fuse size  .  .  .  .  .  .  .  .  .  .  .  .  .  . 15
shippiNg Weight Lbs (Kgs .)  .  . 160 (73)
 
ageNCY ListiNgs  .  .  .  .  .  .  .  .  .  .  .  .

oPeratInG LIMItS

Ambient Temp. Range Air & Water

50° - 100°F (10° - 38°C)

Water Temp. Range

40° - 100°F (4.5° - 38°C)

Water Pressure Ice Maker Water in

Min. 20 psi (1.4 bar)
Max. 60 psi (4.1 bar)

Condenser Inlet Water
(Water cooled only)

Min. 20 psi (1.4 bar)
Max. 60 psi (4.1 bar)

Model No.

Cond. 

Unit

Ice Prod. 

per 24 hrs. 

at 70° Air / 

50° Water 

lbs. (Kgs.)

Ice Prod. 

per 24 hrs. 

at 90° Air / 

70° Water 

lbs. (Kgs.)

Water Used-Gals. (Ltrs.) 

per 100 lbs. of ice 90° 

Air / 70° Water

Kilowatts 
Used per 

100 lbs. 

of ice 90° 

Air / 70° 

Water

Heat 

Rejection 

(Btuh)

Electrical 

Rating

Min. 

Circuit 

Amp.

Ice Prod.

Use

Cond. Use

CCu0150A*11

Air

174 (79)

112 (51)

34

n/a

11.8

3572

115/60/1

9.7

* Represents cube size. For full cube substitute an “F”, for half cube substitute an “H”.

Please note: air-cooled units require 6” (152 mm) clearance for air intake and exhaust.

Note #1: Application bin storage is 100 lbs. (45 Kgs.) = 90% of Internal Volume x 34 lbs. per cubic foot

Note #2: ARI bin storage is 74 lbs. (34 Kgs.) = 80% of Internal Volume x 30 lbs. per cubic foot

1. 90°/70° figures are rated in accordance with ARI Standard 810.

24" (610 mm)

33"

(838 mm)

23 5/8"

(600 mm)

6" (152 mm) to 7" (178 mm)

Adjustable Legs

24" (610 mm)

17 1/2" (444 mm)

16 3/8" (416 mm)

2 5/8" (67 mm)

Electrical Inlet

7/8" (22 mm) D Hole

Icemaker — Water IN

1/4" (6 mm) Male Flare

30 1/16"

(764 mm)

Water Condenser — Water OUT

3/4" (19 mm) FPT

Water Cooled Units Only

Water Condenser — Water IN

3/8" (10 mm) FPT

Water Cooled Units Only

3/4"

(19 mm)

6"

(152 mm)

9"

(229 mm)

4 3/16"

(106 mm)

Icemaker Drain

9/16" (14 mm) I.D. hose

Bin Drain

9/16" (14 mm) I.D. hose

32" (813 mm)

1  7/16" (37mm)

39"

(991 mm)

24"

(610 mm)

Air In - 

Right Front 

of icemaker

Air Out - 

Left Front 

of icemaker

Dimensions and Air Flow

24"

(610 mm)

Cube size:

Width

Depth

heigth

full

7/8" (22mm)

7/8" (22mm)

7/8" (22mm)

half

3/8" (10mm)

7/8" (22mm)

7/8" (22mm)

Отзывы: