Error & Non-Error Messages

The following status messages may be displayed for each cylinder.

Cylinder Status Menu Error Messages:

SYRUP . . . . . . . . . . . . . . . . . . . . . . . . . .syrup sold out - replace syrup

CO2. . . . . . . . . . . . . . . . . . . . . . . . . . . . .sold out - replace CO

2

H2O. . . . . . . . . . . . . . . . . . . . . . . . . . . . .H

2

O sold out 

ERROR . . . . . . . . . . . . . . . . . . . . . . . . . .electronics problem - call service

TIME CLOCK  . . . . . . . . . . . . . . . . . . . . .real time clock error - call service

HOT GAS . . . . . . . . . . . . . . . . . . . . . . . .hot gas condition - call service

VOLT . . . . . . . . . . . . . . . . . . . . . . . . . . . .high or low voltage - call service

DRIVE . . . . . . . . . . . . . . . . . . . . . . . . . . .motor problem - call service

TORQUE. . . . . . . . . . . . . . . . . . . . . . . . .over torque - call service

REFRIG  . . . . . . . . . . . . . . . . . . . . . . . . .freeze cylinder refrigeration or ice bank refrigeration, call ser-
vice

SENSOR . . . . . . . . . . . . . . . . . . . . . . . . .sensor problems - call service

Cylinder Status Menu Non-Error Messages:

ON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .beater bar is turning and refrigeration to this freeze cylinder is 
active

OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . .beater bar is not turning and refrigeration to this freeze cylinder 
is inactive

MOTOR. . . . . . . . . . . . . . . . . . . . . . . . . .beater bar is turning and refrigeration to this freeze cylinder is 
inactive

DFRST  . . . . . . . . . . . . . . . . . . . . . . . . . .freeze cylinder is presently in defrost mode

Solid red LED (just above the display)  . .thermostat has tripped, call for service

Содержание FCB PINNACLE 2 Flavour

Страница 1: ...FCB PINNACLE 2 and 4 Flavor Operator s Manual Release Date November 24 2003 Publication Number 560006533OPR Revision Date September 28 2004 Revision C FCB 2 Flavor FCB 4 Flavor...

Страница 2: ...t have been trained and are skilled in working with electrical plumbing pneumatic and mechanical equipment Appropriate safety precautions should be followed and all local safety and construction requi...

Страница 3: ...ld Out 1 Daily Cleaning 2 Maintaining Product Quality Cornelius FCB Equipment Operator Instructions 2 1 Dispensed Product Throughput 2 Dispensed product throughput matrix 2 2 Programmed Defrost Schedu...

Страница 4: ...FCB Pinnacle 2 and 4 Flavor Operator s Manual Publication Number 560006533OPR ii 2003 04 IMI Cornelius Inc...

Страница 5: ...the syrup tube first then the CO2 tube 2 Rinse the disconnects in warm water to remove any syrup residue 3 Move a full Syrup tank into position and connect the CO2 tube first then the syrup tube 4 Ret...

Страница 6: ...ornelius makes the following recommendations to help assure maximum product quality 1 Dispensed Product Throughput FCB equipment is designed to provide a high throughput of frozen carbonated dispensed...

Страница 7: ...crystal size growth As the ice crystal size increases however there is potential for product quality to diminish Cornelius recommends that the viscosity settings be set at the lowest possible setting...

Страница 8: ...menu displays the system clock and the present status of each cylinder see Figure 4 Barrel Status Menu Button Descriptions 1 MENU bring up the Choose Mode menu menu 2 service use only 2 ON turn all c...

Страница 9: ...ce VOLT high or low voltage call service DRIVE motor problem call service TORQUE over torque call service REFRIG freeze cylinder refrigeration or ice bank refrigeration call ser vice SENSOR sensor pro...

Страница 10: ...IMI Cornelius Inc www cornelius com...

Отзывы: