![Cornelius ENDURO 250 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/cornelius/enduro-250/enduro-250_service-manual_2667805010.webp)
Chiller Service Manual
Publication Number: 620920816SER
- 6 -
© 2005, IMI Cornelius Inc.
5.
Warm beer
A.
Defective Pump (check motor
also)
A.
Check return line in reservoir
for liquid flow. Replace pump
B.
Defective motor (check pump
also)
B.
Replace motor
C.
Refrigeration unit not running
C.
Refer to 2
D.
Conduit lines located in
overheated area
D.
Remove from any hot water
pipes or kitchen area with
stove or glass washer.
E.
Conduit lines flooded in PVC
chase.
E.
Remove lines from PVC,
thoroughly dry PVC and
repair or replace conduit as
needed.
F.
Uninsulated or poorly
insulated lines
F.
All lines should be fully
insulated from cooler into
dispenser. Includes glycol
lines from power pack into
cooler.
G.
Thermostat
G.
Adjust temperature to colder
setting.
H.
Condenser fan motor not
working
H.
Replace condenser fan
motor.
I.
Freon leak
I.
Repair leak and recharge.
J.
Dirty condenser
J.
Clean the condenser
K.
Condensation inside conduit
insulation (may be caused
from cleaning lines)
K.
Check trunk housing in areas
for drooping or low spots,
split insulation approximately
5” and separate. Allow any
water to drain, then air dry,
the seal closed.
L.
Warm walk in cooler
L.
Check temperature of walk-in
cooler-liquid temperature, set
cooler at 36
o
to 38
o
.
Содержание ENDURO 250