Ice/Beverage Dispenser Installation Manual
©2004-2015, Cornelius Inc.
- 2 -
Publication Number: 92166INS
S
AFETY
P
RECAUTIONS
This unit has been specifically designed to provide protection against personal injury. To ensure continued protection
observe the following:
!
WARNING
:
Disconnect power to the unit before servicing following all lock out/tag out procedures established by the user. Verify
all of the power is off to the unit before any work is performed.
Failure to disconnect the power could result in serious injury, death or equipment damage.
CAUTION
:
!
Always be sure to keep area around the unit clean and free of clutter. Failure to keep this area clean may result in
injury or equipment damage.
S
HIPPING
A
ND
S
TORAGE
CAUTION
:
!
Before shipping, storing, or relocating the unit, the unit must be sanitized and all sanitizing solution must be drained
from the system. A freezing ambient environment will cause residual sanitizing solution or water remaining inside the
unit to freeze resulting in damage to internal components.
CO
2
(C
ARBON
D
IOXIDE
) W
ARNING
!
DANGER
:
CO
2
displaces oxygen. Strict attention
MUST
be observed in the prevention of CO
2
gas leaks in the entire CO
2
and
soft drink system. If a CO
2
gas leak is suspected, particularly in a small area,
IMMEDIATELY
ventilate the
contaminated area before attempting to repair the leak. Personnel exposed to high concentrations of CO
2
gas
experience tremors which are followed rapidly by loss of consciousness and
DEATH.
P
OWER
C
ORD
If the power cord is damaged, it must be replaced by a special cord available from the manufacturer or its service
agent.
M
OUNTING
IN
OR
ON
A
C
OUNTER
!
WARNING
:
When installing the unit in or on a counter top, the counter must be able to support in excess of the total operating unit
weight.
Failure To Comply Could Result In Serious Injury, Death Or Equipment Damage.
N
OISE
L
EVEL
This unit emits acoustical noise with an A-weighted sound pressure level no greater than 70dB, as measured in
accordance with ED 60335-2-75.
NOTE: Many units incorporate the use of additional equipment such as icemakers. When any addition
equipment is used you must check with the equipment manufacturer to determine the additional weight the
counter will need to support to ensure a safe installation.
Содержание ED 300 BC
Страница 22: ...Ice BeverageDispenserInstallationManual 2004 2015 Cornelius Inc 18 Publication Number 92166INS Figure 13...
Страница 24: ......
Страница 25: ...Cornelius Inc www cornelius com...