Continue to activate the dispensing valve in cycles (“ON” for 15-seconds, “OFF”, then “ON” for
15-seconds). Repeat “ON” and “OFF” cycles for 15-cycles.

3. Connect detergent solution to remaining syrup systems and flush syrup out of syrup systems as instructed

in step 2 preceding.

4. Remove detergent solution source from the syrup system.

STEP 2. FLUSH COOLING SYSTEMS

Tank Systems.

1. Connect tank containing potable water, pressurized at 60 to 80-psi, into one of the tubing systems.

Bag-in-Box Syrup System.

2. Fill five-gallon container with potable water, then place all bag-in-box syrup containers syrup outlet tubes in

container containing potable water.

A.

Flush detergent solution out of syrup system and dispensing valve as follows:

B.

Place waste container under applicable dispensing valve.

C.

Activate the dispensing valve for one minute to purge all detergent solution and flush out of the syrup
system.

D.

Continue to activate the dispensing valve in cycles (“ON” for 15-seconds, “OFF”, then “ON” for
15-seconds). Repeat “ON” and “OFF” cycles for 15-cycles.

3. Connect potable water source to remaining syrup systems and flush detergent solution out of syrup sys-

tems as instructed in step A preceding.

4. Remove potable water source from the syrup system.

STEP 3. SANITIZE COOLING SYSTEMS

1. Using a clean tank (tanks system) or a five-gallon container (bag-in-box system), prepare sanitizing solu-

tion using 70

°

F (21

°

C) to100

°

F (38

°

 C) potable water and 0.5 oz. (15 ml) of household liquid bleach such

as non-scented Hi-Lex or Chlorox that contains a 5.25 % sodium hypochlorite concentration to one gallon
of potable water.This mixture 

must not

 exceed 200 PPM of chlorine. Shake sanitizing solution to thoroughly

mix.

Tank Systems.

A.

Connect sanitizing solution tank, pressurized at 60 to 80-psi, into one of the tubing systems.

Bag-in-Box Syrup System.

B.

Place all bag-in-box syrup containers syrup outlet tubes in container containing sanitizing solution.

2. Sanitize the syrup system and dispensing valve as follows:

A.

Place waste container under applicable dispensing valve.

B.

Activate the dispensing valve for one minute to purge all water from and install sanitizing solution in
the syrup system and dispensing valve.

C.

Continue to activate the dispensing valve in cycles (“ON” for 15-seconds, “OFF”, then “ON” for
15-seconds). Repeat “ON” and “OFF” cycles for 15-cycles.

3. Repeat steps to flush water out of and install sanitizing solution in the remaining syrup systems and dis-

pensing valves.

Содержание Drop-In and Free-Standing Ice Cooled Dispensers

Страница 1: ...oute and connect unit ice bin and drip tray drain hoses All drains and connections to such drains must meet local plumbing codes Units with electrically operated valves must be located near a properly...

Страница 2: ...g Solution Using a clean tank tanks system or a five gallon container bag in box system prepare sanitizing solution using 70 F 21 C to100 F 38 C potable water and 0 5 oz 15 ml of household liquid blea...

Страница 3: ...p systems and flush detergent solution out of syrup sys tems as instructed in step A preceding 4 Remove potable water source from the syrup system STEP 3 SANITIZE COOLING SYSTEMS 1 Using a clean tank...

Страница 4: ...FF then ON for 15 seconds Repeat ON and OFF cycles for 15 cycles 3 Repeat preceding steps to purge sanitizing solution out of the remaining syrup systems and dispensing valves 4 Remove potable water s...

Страница 5: ...nits must have a pre mix supply connected to each inlet for each valve to be supplied Refer to the plumbing diagram for details of the hook up Note A plumbing diagram when supplied with the unit can b...

Страница 6: ...I CORNELIUS INC MASON CITY IA DRINK DISPENSERS VALVE TYPE MANUFACTURER PORTION CONTROL MAXIMUM OPERATING PRESSURE CORNELIUS 130 psi LANCER 100psi FLOWMATIC 100psi McCANN 130psi PUSH BUTTON CORNELIUS 1...

Страница 7: ...ensing valve syrup flow regulator G Tapered nylon washer inside tube swivel nut connector distorted from being overtightened G Replace nylon washer and make sure it seats properly ADJUSTMENT OF DISPEN...

Страница 8: ...ion E Warm Product No ice in bin bridged ice on cold plate or plugged drain E Replenish ice break ice up to eliminate bridging unplug the drain NOTE If water supply is dirty be sure to flush lines and...

Страница 9: ...nes restricted G Sanitize syrup system as instructed ONLY SYRUP DISPENSED A Plain water inlet supply line shutoff valve closed A Open plain water inlet supply line shutoff valve B Carbonator power cor...

Отзывы: