background image

COLD NITRO BREW DISPENSER

Model: CNB BIB 

Installation Manual

Release Date: 9/26/17

Publication Number: 621058723INS

Revision Date: 3/14/18

Revision: Rev. A

Visit web site http://cornelius-usa.com and create an account for all your literature needs.

Содержание CNB BIB

Страница 1: ...ENSER Model CNB BIB Installation Manual Release Date 9 26 17 Publication Number 621058723INS Revision Date 3 14 18 Revision Rev A Visit web site http cornelius usa com and create an account for all yo...

Страница 2: ...failure to utilize suitably qualified and trained persons to perform service and or repair of the Product 10 improper cleaning 11 failure to follow installation operating cleaning or maintenance instr...

Страница 3: ...System Overview 5 Overview 5 Features 5 Specifications 6 Installation 7 Delivery Inspection and Unpacking 7 Installation Kit 7 Location 7 Supply Connections 8 Electrical Requirements 8 Line Voltage 8...

Страница 4: ...Unit Cleaning and Sanitation 25 Changing Coffee Types 30 Unit Foam Head Height Adjustment 31 System Diagrams 33 Electrical Diagram 33 Nitrogen Flow Diagram 34...

Страница 5: ...ardous situation which if not avoided WILL result in serious injury death or equipment damage DANGER Indicates a potentially hazardous situation which if not avoided COULD result in serious injury dea...

Страница 6: ...e continued protection observe the following WARNING Disconnect Power When Servicing Disconnect power to the unit before servicing follow ing all lock out tag out procedures established by the user Ve...

Страница 7: ...cial cord available from the manufacturer or its service agent SOUND LEVELS CAUTION The A weighted sound pressure level has been determined to be below 60 dBA MACHINE USAGE CAUTION This unit is not in...

Страница 8: ...nnection of the equipment grounding conductor can result in a risk of electrical shock The conductor with green insulation with or without yellow stripes is the equipment grounding conductor If repair...

Страница 9: ...double dispenser lever interface Easy to Clean dispense area is easily wiped down Small Footprint CNB BiB design allows the unit to be installed remotely and under counter with minimum space requirem...

Страница 10: ...Capacity 2 3 gallon BiBs Approx box Dimensions 13 1 2 H x 7 1 2 W x 9 1 2 D Cabinet Door closed not including tower 30 1 76 5 cm D includes standoffs x 20 50 8 cm W x 34 86 4 cm H Cabinet Door closed...

Страница 11: ...Cold Nitro Brew BIB Dispenser Installation Manual 2017 Cornelius Inc 7 Publication Number 621058723INS...

Страница 12: ...age possible and contact the freight company immedi ately 2 Remove the strapping from the box remove the tape and lift the carton off the pallet 3 Remove the internal packing materials and installatio...

Страница 13: ...wn in Figure 2 The unit is filled manually from the front Figure 2 Electrical Requirements WARNING Refer to the nameplate to determine the power requirements before connecting electrical power to the...

Страница 14: ...dicated secondary regulator adjusted to 80 psi 0 55 MPa to supply the unit Nitrogen Connections WARNING Only trained and certified electrical plumbing and refrigeration technicians should service this...

Страница 15: ...ster pump preceding the dispensing equipment is provided with back flow protection by an air gap as defined in ANSI A 112 1 2 1979 or an approved vacuum breaker or other such method as proved effectiv...

Страница 16: ...ailure FREESTANDING UNIT INSTALLATION WARNING Only trained and certified electrical plumbing and refrigeration technicians should service this unit NOTE Read the entire manual before installing the CN...

Страница 17: ...5 Route the 1 4 ID Tygon tubing from the nitrogen tank to the CNB BIB unit and connect the tubing to the Nitrogen inlet using a hose clamp 6 Install the tap units to the dispensing tower couplings The...

Страница 18: ...bing to the water source fitting B Route the tubing from the water source to the CNB BIB Water inlet as shown in figure 1 or to the water booster pump inlet shown at right C Connect the tubing using a...

Страница 19: ...wards and pull bottom towards the front to disengage the locking tabs in the bottom frame assem bly B Unfasten cover remove 2 screws at top of cover C Slide filter to the left 13 Open the ice bank wat...

Страница 20: ...oom temperature water is 6 hours NOTE The ice bank typically requires a water refill every month Observe the water level shown in the fill tube with red cap Remove cap for accurate reading 15 Replace...

Страница 21: ...n top of liner 18 Connect the CNB BIB unit power cord to the socket on the back of the unit Move the dispenser unit into the selected location 19 Open the nitrogen tank hand valve A The left side gaug...

Страница 22: ...S INJURY DEATH OR EQUIPMENT DAMAGE Table 3 Step Action 1 Remove the staples holding the box to the skid Unpack the CNB BIB unit remove the installation kit boxes from the unit and inspect the unit and...

Страница 23: ...ce holes for tower mounting hardware 6 A Locate Adapter Ring in accessories kit B Align adapter ring to drilled holes underneath the counter and tape in place 7 A Route the 1 4 ID Tygon tubing from th...

Страница 24: ...water lines through counter hole into cabinet opening E Locate and use four 10 screws in accessory kit select proper screw length for specific counter top installa tion 10 Install the tap units to the...

Страница 25: ...tment C Hook up the blue tower cooling line 3 to the 3 8 inch braided line coming from the bottom of the cabinet Use the large hose clamp supplied in the accessory kit D Hook up the red tower cooling...

Страница 26: ...he top of the unit and the counter top Use the supplied silicone from the acces sories kit 16 Access the ice bank for water filling A Lift grill upwards and pull bottom towards the front to disengage...

Страница 27: ...also be filled with chilled water to reduce the time for cool down to 33 F 0 C Typical cooling time using room temperature water is 6 hours NOTE The ice bank typically requires a water refill every m...

Страница 28: ...he 3 8 ID tubing to the water source fitting B Route the tubing from the water source to the CNB BIB Water inlet or to the water booster pump inlet shown at right C Connect the tubing using a large ho...

Страница 29: ...nses still cold brew coffee and the right tap dispenses Nitro cold brew coffee NOTE When dispensing pull the tap handles all the way forward and down Figure 5 Cleaning Products KAY 5 Cleaner Sanitizer...

Страница 30: ...the cleaning process have the following ready Two 1 gallon buckets one white cleaning adapter and approved Sanitizer To clean and sanitize the unit the product tubing and the tower dispenser perform t...

Страница 31: ...so that the connector will stay at the bottom 6 Turn the Sanitizing Valve to the Dispense position and the Nitrogen valve to the OFF position 7 A Open LEFT tower dispenser and dispense 0 25 gallons 1...

Страница 32: ...itizer cleaner solution B Close the tap C Open RIGHT tower dispenser and dispense 0 25 gallons 1 quart of sanitizer cleaner solution D Close the tap E NOTE DO NOT OPEN BOTH VALVES AT THE SAME TIME AS...

Страница 33: ...ap C Open RIGHT tower dispenser and dispense 0 25 gallons 1 quart of sanitizer cleaner solution D Close the tap E NOTE DO NOT OPEN BOTH VALVES AT THE SAME TIME AS DISPENSING MAY PULSE OR EVEN STOP 18...

Страница 34: ...ainer with sani tizer cleaner solution C Close the cabinet door 22 A Soak the BIB product line and nozzles for 15 minutes B While the parts are soaking wipe the outside inside tower drip tray and valv...

Страница 35: ...sh the hose straight into the BIB OUT port until it locks in place 26 A Obtain a product BIB B Place it in the cabinet outlet port towards the base of the cabinet and connect the BLACK product output...

Страница 36: ...procedure in Table 5 to adjust the foam head height on the CNB BIB unit Table 5 Step Action 1 Make sure the Nitrogen tank is open or the nitrogen gener ator is turned on The primary side gauge should...

Страница 37: ...Repeat and dispense another 12 oz to confirm setting C Repeat step A if a further reduction of foam head height is required 6 INCREASED FOAM HIGHT adjustment A Adjust the regulator control knob sligh...

Страница 38: ...Cold Nitro Brew BIB Dispenser Installation Manual Publication Number 621058723INS 33 2017 Cornelius Inc SYSTEM DIAGRAMS ELECTRICAL DIAGRAM Figure 6...

Страница 39: ...Cold Nitro Brew BIB Dispenser Installation Manual 2017 Cornelius Inc 34 Publication Number 621058723INS NITROGEN FLOW DIAGRAM Figure 7...

Страница 40: ...Cold Nitro Brew BIB Dispenser Installation Manual Publication Number 621058723INS 35 2017 Cornelius Inc...

Страница 41: ......

Страница 42: ...Cornelius Inc www cornelius usa com...

Отзывы: