4
91487
GATE RESTRICTOR PLATE
CAUTION:
Disconnect power to dispenser before installing, removing or adjusting
restrictor.
INSTALL PLATE ON
STUDS AS SHOWN
FIGURE 2. GATE RESTRICTOR PLATE
ADJUSTMENT
This dispenser is provided with a gate restrictor plate, installed in it’s highest position. This plate adjusts the rate
of ice flow from the dispenser. In applications using buckets, carafes, or other large containers, the plate may be
removed entirely for maximum ice flow. For glasses and cups, the plate may be adjusted downward to reduce
the flow of ice. The best position depends on the type of ice being used and the size container and must be
found by trial and error. Adjustment is made by loosening the upper two ice chute retaining nuts, sliding the re-
strictor plate to the desired position and retightening the nuts.
If the dispenser fails to dispense the ice when operated, check that the hopper has ice in it and that power is
being supplied to the unit. If the problem persists, check the following:
1. Determine if the agitator is rotating (check for the sound of ice movement in the hopper)
2. Observe whether the gate is opening.
Содержание 2230 AK6