Description
Cornelius Deutschland GmbH
Document no. TD1002000
Version 01/10/2019, Index 2
Operator manual Undercounter cooler
Energize 2-5 HC
27
3.3.9
Control and indicator panel
Carbonator pump switch
Circulation pump switch
Compressor switch
LED red - alarm
LED orange - CO
2
alarm
LED green - power/mains
Fig. 13
1
2
3
4
5
6
LED
Status
Description
Comment
Alarm (red)
Off
OK
No existing error
On
Not OK
see chapter 6.1
Flashing 1 Hz
Not OK
see chapter 6.1
Flashing 4 Hz
Not OK
see chapter 6.1
CO
2
alarm (orange)
Off
OK
CO
2
pressure is available
On
Not OK
see chapter 6.1
Power/mains (green)
On
OK
Voltage in permitted section
Flashing 1 Hz
Not OK
see chapter 6.1
Flashing 4 Hz
Not OK
see chapter 6.1
Alarm (red) + power/
mains (green)
Flashing
alternately
Not OK
see chapter 6.1