Installation and service manual: Postmix tower
Ribbon
29
Cornelius Deutschland GmbH
Document no. TD0000100
Version: 06/11/2017, Index 0
5.6
Removing the unit
1.
Disconnect all tubes (Figure 25/1) from the python
(Figure 25/2).
2.
Attach a cap to each tube.
3.
If applicable, remove the drain set;
4.
Remove the threaded bolts (Figure 26/3), nuts
(Figure 26/1) and washers (Figure 26/2) used to attach
the unit to the supporting structure.
Prerequisites
Reference
The undercounter cooler has been shut
down.
See the document
“Undercounter cooler
installation and service manual”.
The unit has been shut down.
The drip tray has been removed.
.
Required tools/materials
ID/
Reference
Qty/
amount
Comment
Undercounter cooler instal-
lation and service manual
Document no: various 1
Figure 25
1
2
Figure 26
3
2