background image

 

 

6. Product Data sheets 

Product data sheet

 

 

 

                                  

Index

21 AC 

Model 

06 1 3601XX

 

Date:   

25 Feb 2010 

 

 

 

 

            

 

Issue No: 

 

Performance

 

Nominal icebank pull down:( water 10

o

C at 24

o

C ambient) 

 

5 hours 

Icebank weight:  

25kg nominal 

Thermal capacity icebank: 

 

 

 

8375KJ  (2000 Kcal) 

Maximum ambient temperature:  

 

43

o

 

Dimensions 
Height:  

930mm 

Width:   

570mm 

Depth:   

600mm 

Weight: Unloaded 

66kg 

             Packed 

67kg  

             Operational 

130kg  

 

Electrical 
Mains supply: 

230v 1ph 50Hz 

Run current: 

5.0 amps 

Start current: 

31 amps 

Fuse: 

10 amps 

Supply: 

2m mains cable 3 pin UK 

Style plug 

 

Refrigeration 
Compressor: 

21cc 

Compressor starting torque: 

High starting torque 

Compressor duty: (-10

o

C Evap temp) 

750 watts 

Evaporator type: 

12.7mm dia tube 

Condenser type: 

Air Cooled – Cu/Al construction 

Expansion device: 

Capillary 3M x 1.5mm I.D. 

Refrigerant type charge: 

R134a refer rating plate  

Control type: 

Mechanical thermostat 

 

Fan Motor 
Output: 

11 watts 

Speed: 

1300 rpm 

Direction: 

Counter clockwise shaft end 

Protection: 

Impedence 

Fan blade: Diameter 

250mm 

                  Pitch 

28

o

 

 

 
 

 

Содержание 06 1 3601 Series

Страница 1: ...Model Number Range 06 1 3601XX 06 1 3602XX Applies to Index remote cooler range Index21 AC Air cooled models with part code commencing 06 1 3601XX Index21 WC Water cooled models with part code commenc...

Страница 2: ...Contents Section Content 1 Introduction 2 Installation Instructions 3 Service Maintenance instructions 4 Fault Finding 5 Product Photos 6 Data Sheets 7 Parts Lists and exploded views 8 Wiring Diagrams...

Страница 3: ...educed life costs The Index is built to BDA standards ensuring that the lid is interchangeable there is simple exchange of serviceable parts and standard cassette product coils Index also has a small...

Страница 4: ...in 2m of unit INDEX 21 AC air cooled Outside a chilled cellar close to beer storage Ambient temperature 10 to 43 C INDEX 21 WC water cooled Base unit inside chilled cellar Ambient temperature o Base u...

Страница 5: ...NG Indicates an immediate hazardous situation which if not avoided COULD result in serious injury death or equipment damage CAUTION Indicates an immediate hazardous situation which if not avoided MAY...

Страница 6: ...n hatch on the lid of the cooler Fill with cool clean water until liquid starts to flow from the overflow Stop filling and close the filler inspection hatch on the lid of the cooler The overflow is a...

Страница 7: ...cient glycol water mixture is available for filling the coolant bottle and topping up during priming before switching the remote W C cooler on You will need to prepare 4 litres of glycol water mix to...

Страница 8: ...roduct coils of the remote cooler Utilize 3 8 push fit connectors Note All lines to be well insulated to the requirements of the system Operation Once connected to the mains electrical supply allow ti...

Страница 9: ...evel If the cooler becomes noisy makes a gurgling sound this is due to a low product bath water level and will result in reduced cooling capacity To remedy this follow the instructions for Filling the...

Страница 10: ...er level in the water bath is up to the overflow Check that the Discharge Unit fan is working and that there are no obstructions or blockages of the air vents Check and clean the heat exchanger fins o...

Страница 11: ...s c Always isolate electrical supply before undertaking repairs No Compressor doesn t start hums and trips on overload Yes a Start capacitor shorted or blown b Start relay will not close or is burned...

Страница 12: ...d recharge e Leave for an hour If ice bank still does not reform check specification against location f Refill with 30 Glycol 70 Water g Replace h Ensure all valves are open Check lines are not kinked...

Страница 13: ...5 Product Photos Index21 AC Heat Dump Exchange Unit Index21 WC...

Страница 14: ...l Mains supply 230v 1ph 50Hz Run current 5 0 amps Start current 31 amps Fuse 10 amps Supply 2m mains cable 3 pin UK Style plug Refrigeration Compressor 21cc Compressor starting torque High starting to...

Страница 15: ...Length Max Qty Short 3 8m 12 Long 5 4m 12 Super Long 8 0m 8 Material 316 stainless steel Compliance to Standards and Legislation All coolers comply with Brewers Society Code of Practice for Electrica...

Страница 16: ...tart current 31 0 amps Fuse 10 amps Supply 2m mains cable 3 pin UK Style plug Min 1 5mm2 minimum cable from base unit supplied by Installer Refrigeration Compressor 21cc Compressor starting torque Hig...

Страница 17: ...upled drive max lift min flow 15m Product Coils Length Max Qty Short 3 8m 12 Long 5 4m 12 Super Long 8 0m 8 Material 316 stainless steel Other Controls Refrigeration system cut out Manual reset Compli...

Страница 18: ...t capacitor danfoss 8 06 0 274007 Fan motor mod d 9 06 0 361107 Fan motor bracket 9a 220104050 Fan cowl moulded see alternative view below 10 44 0000 058 Fan blade 11 58 1174 007 Icebank thermostat me...

Страница 19: ...Exploded View Index21 AC Model 06 1 3601XX 1 2 4 6 7 8 11 3 5 10 12 14 15 16 17 9 13...

Страница 20: ...0440 429 Transformer 9a 58 0420 610 Glycol pump totton 9b 58 0420 570 Glycol pump marchmay 10 58 0446 198 24v connector 11 58 1174 007 Icebank thermostat mechanical 12 58 0475 214 Lifting handle lid...

Страница 21: ...Exploded View Idex21 WC Model 06 1 3602XX 3 20 1 15 17 12 4 10 6 8 9 11 13 19 2 7 14 5 16 18...

Страница 22: ...8 Wiring Diagram Index21 AC Model 06 1 3601XX...

Страница 23: ...Index21 WC...

Страница 24: ......

Отзывы: