background image

Advanced Installation Procedure

U n p a c k   C a r t o n   C o n t e n t s

a ) Po w e r l i n e   t o   C o a x   c o u p l i n g

b ) I n d u c t i v e   c o u p l i n g

C o n n e c t   t h e   M D U   G a t e w a y

1. Install 3 USB cables into the MDU Gateway.
2. Connect the MDU Gateway power cord to the MDU Gateway and to 
an electrical outlet.
3. Connect the RJ45 Ethernet cable to an Internet router and to the 
MDU Gateway.

4.  Ensure  each  electrical  phase  is  connected  to  an  electrical  outlet 
near the MDU Gateway. If the outlets are not available, an electrician 
must  install  them.  There  are  3  methods  for  MDU  Gateway  signal 
coupling, use only one of these methods:
a) Powerline to Coax coupling
b) Inductive coupling
c) Capacitive coupling

1. Connect the 1m coax cable to module 1 (or any of the modules, but 
only one) of the MDU Gateway, connect to the RF splitter input.
2.  Connect  the  3  other  1m  coax  cables  to  the  3  outputs  of  the  RF 
splitter.
3. Connect the 3 Powerline to Coax couplers to the 3 coax cables.
4. Connect 3 Powerline signal coupling cables to the 3 Powerline to 
Coax Couplers.
5.  Connect  each  of  the  3  powerline  signal  coupling  cables  to  each 
electrical phase (1 outlet for each phase). 
6. Continue with the Basic Installation Procedure from step number 6.

1. Connect the Powerline signal coupling cable B to the MDU Gateway 
module 1  (or any of the modules, but only one) power outlet.
2. Connect each of the 3 powerline signal loop cables to each electri-
cal phase (1 outlet for each phase). 
3. Continue with the Basic Installation Procedure from step number 6.  

1. Connect the 1m coax cable to module 1 (or any of the modules, but 
only one) of the MDU Gateway, connect to the 11+1 Coupler input.
2. Connect 3 Powerline signal coupling cables to the 11+1 Coupler.
3.  Connect  each  of  the  3  powerline  signal  coupling  cables  to  each 
electrical phase (1 outlet for each phase). 
4. Continue with the Basic Installation Procedure from step number 6.  

c ) C a p a c i t i v e   c o u p l i n g

1

2

3

MDU Gateway

Breaker Panel

Electric Outlet

1 0 . 1 0 . 1 . 1
M o d u l e   1

2

3

3

3

1

4

4

4

5

5

5

( 3 - P h a s e   Po w e r )

Breaker Panel

Electric Outlet

Breaker Panel

Electric Outlet

MDU Gateway

1 0 . 1 0 . 1 . 1
M o d u l e   1

1

2

2

2

MDU Gateway

1

2

2

2

3

3

3

(1) MDU Gateway
(10) AV200 Powerline Ethernet Adapters
(3) USB cables
(1) MDU Gateway power cord
(11) RJ45 Ethernet cables
(3) Powerline signal coupling cables
(3) Powerline to Coax couplers
(1) 11+1 coupler
(1) Powerline signal coupling cable B
(3) Powerline signal loop cables
(4) 1m coax cables
(6) Inductive couplers 
(1) RF splitter

RJ45 Ethernet cables

Powerline signal coupling cable

MDU Gateway power cord

1. Carefully unpack all of the components from the carton.
2. The package contents should include:

RF splitter

USB cable

Powerline signal loop cable

1 m coax cable

MDU Gateway

CXP-MDU-GWY

AV200 Powerline Ethernet Adapter

CXP-AV200-ETHe

Powerline to Coax coupler

CXZ-CXP-CXC

Powerline signal coupling cable B

Inductive coupler

11+1 coupler

4

CXZ-CXP-PH12

Breaker Panel

Electric Outlet

Note: The electrician may 
connect  the  powerline 
signal  coupling  cables 
directly  to  the  breaker 
panel  to  avoid  installing 
the 3 electrical outlets.

B

as

ic

 

In

st

al

la

ti

o

n

A

d

va

n

ce

d

 

In

st

al

la

ti

o

n

Office Connect 600

Quick Start Guide

CXP-OC600

F o r   u p   t o   2 0   u s e r s   o n   m u l t i p l e   e l e c t r i c a l   p h a s e s *

* For greater than 20 users or for utilizing more than one module on the MDU Gateway please see the  Corinex Professional MDU Networking Installation and User Manual

Отзывы: