10. Technical Data
Table 4: Technical Data
Electrical Data
Input Voltage
Max. Input Current 1.3 [A]*
Output Voltage on L+
Equals to Input Voltage
**
Typical Current Consumption
21 [mA]**
*
Max Output Supply Current
1 [A]
Max Output Peak Current
1.2 [A]***
*
Wireless Parameters
Operating Frequency
2.4 GHz ISM Band
Communication Standard
IO-Link Wireless
Modulation
GFSK, Modulation index = 0.5
Radio Peak Output Power
10 [dBm]
Interfaces
LEDs
•
IO-Link
– RGB three color LED
•
Power
– Green color LED
Button
Pairing - external push button
Connectors
•
Input connector: Plug M12, A coded, power Connector
o
Pin number 1: Input L+ Power supply
o
Pin number 3: Input L- GND
•
Output Connector: Socket M12, A coded, IO Link Class A Connector
o
Pin number 1: L+ positive supply to IO Link device
o
Pin number 3: L- GND supply to IO Link device
o
Pin number 4: CQ IO Link Serial Communication
Antenna
Internal isotropic antenna
Communication
Protocols
•
IO Link
o
Supported transmission types: COM1, COM2, COM3
o
Revision 1.1
o
Class A
•
IO Link Wireless
o
Version 1.1
Operating Frequency Bands
2401
– 2480 [MHz]
Maximum radio-frequency
power
10 [dBm]