Mount the gSC2 in the desired location

The gSC2 is designed to mount on a shelf, hang in a cabinet  
or rack, or mount in a structured wiring enclosure. 

Shelf Mounting:

 

The gSC2 has rubber feet to protect finished surfaces. 
Set the gSC2 in a location that will allow you to properly  
manage connected wiring so that tension is not placed on the  
connections. The gSC2 is relatively small and wire tension  
will cause the unit to move and may cause wires to become 
disconnected. 

Dimension:

 8-1/2” W x 1-9/16” H x 5” D (half rack) 

(215.9mm W x 39.69mm H x 127mm D)
 

Wall Mounting:

 

The Wall Mounting Brackets included with the gSC2 attach to the 
chassis using the included screws. 
 
Do not use longer screws to attach the brackets as this may  
permanently damage the gSC2. Utilizing the Wall Mount Brack-
ets the gSC2 may be mounted in any orientation that suits your  
installation.  

Using the unit with the attached brackets as a template mark 
the keyhole screw locations and the security screw  locations.  
Pre-drill all holes and insert only the keyholes screws. Hang the 
gSC2 on the keyholes screws and then insert the security screws.

  

 

Structured Wiring Cabinet Mounting: Mounting the gSC2 in  
a structured wiring cabinet is essentially the same as Wall 
Mounting it. The difference is that you must supply mounting 
screws that are short enough to not penetrate through the wall 
behind the enclosure. 

1

To protect your equipment from power surges and momentary power interruptions we strongly  

suggest you utilize a battery-backed power supply (UPS) with this equipment.  

 

ELAN recommends Panamax UPS and power conditioning products for use with your new gSC2.

Unpack the gSC2.

 Verify that you have all packaging contents.  

You should have received: 

 

 

 
 

a.

 

gSC2 

   

f.

 1ea RJ-45 to serial DB-9 

 

b.

 12vDC Power Supply 

 

    null modem adaptor (P/N 8900599)

 

c.

 Wall mounting brackets 

 

g.

 Relay wiring connector

 

d.

 Wall mounting hardware 

 

h.

 WiFi antenna

 

e.

 2ea RJ-45 to serial DB9 male adaptors 

i.

 Quick Install Guide (this document) 

 

    (P/N 8900597) 

 

The g! Training Guide contains valuable hardware and software reference documentation and is considered  
an important supplement to this document. You would have received the training guide while attending  
g!School, however the g! Training Guide is updated regularly. Make sure you have the latest version by visiting 
the ELAN Dealer website at www.elanhomesystems.com and following the “dealer” link. 

Note:

 

The gSC2 does not have a ViaNET connection. If your installation has devices that require  

ViaNET communication you will need to connect an ELAN SC1 to one of the serial RS-232 ports. 

     

www.elanhomesystems.com

 

 

Relay Connections

Two normally open relays are available for controlling 
third party devices. The included removable connector will  
accept up to 16ga bare copper leads. Be careful to verify  
that no portion of one wire touches the other wire. Prior to  
connection verify that the connected load does not exceed 24volts 
AC/DC or 1amp. If either parameter is exceeded, add a higher  
capacity relay to control the load and use the gSC2 output to  
control that relay.
  
 

Sense Input Connections

ELAN sensors can be used to input a status from 3rd party  
devices. The status can either be ON or OFF. This can be used to 
trigger an event map or as a condition of an event map. Connect 
ONLY ELAN sensors to these ports.

3

4

DC Power

Connection

Serial 

Connections

2 bi-directional RS-232 Ports 

Sense Input

Connections

2 ELAN Sensor
input Ports 

IR Outputs

4 discrete IR channels.
Compatible with Xantech 
single and dual emitters.

USB Modem Connections

USB - See Integration Notes for compatible equipment

Ethernet Connection

Ethernet - 10/100 Mbps
PoE IEEE 802.3at Type 2
48 VDC, 600 mA 

Relay 

Connections

2 Normally Open Relays
12VDC 24VAC @ 1 
AMP Compatibility

WIFI Antenna

802.11 b/g/n 

Reset

Reset's the 
unit's IP  address 
to factory default 
(DHCP). 

Press and hold 
for programming 
reset.

Factory use

ONLY

Available ELAN sensors include: AUDIO, VIDEO, CONTACT CLOSURE,  
VOLTAGE, LED/LIGHT, and CURRENT/MAGNETIC FIELD sensors.

E L A N  

                                                       

HC4/HC8 

INSTALLATION MANUAL

 

©

 

ELAN 2010 

|

 All rights reserved

 

Page 24 

 

Sense Input Connections 

The Sense Inputs of the HC4 (2) / HC8 (4) are used to conditionally execute macros and to 
trigger Event Maps that have been programmed into the System Controller using the ELAN 
configuration software. 

When used with a conditional macro the sensor is connected to the device being 
monitored.  The ELAN configuration software can be used to create a macro that checks 
the status of the sensor prior to issuing a command.  This “conditional programming” can 
be used to prevent a TV, for example, from being inadvertently turned on or off when 

changing sources or turning a zone on or off. 

Event Maps can be programmed that execute a command or sequence of commands when 
a Sense Input is triggered.  For example, a driveway sensor can be used to activate an 
ELAN contact closure sensor to trigger an Event Map that turns on the outside lights.  The 
status of a light sensor can be used to make the triggering of the Event Map conditional.  If 

it is daytime the lights don’t come on.  If it is nighttime, they do. 

The HC4/HC8 pr5 VDC to the TIP (VSNS) connection to power the Sensor.  When 
the Sensor is activated, it shorts the ring (SNS) to the sleeve (GND) thereby triggering the 

HC4/HC8’s Sense Input.  See Figure 3-7. 

Figure 3-7: Sense Inputs 

 

 

 

 

 

 

 

 

 

Available ELAN sensors include: AUDIO, VIDEO, CONTACT CLOSURE, and VOLTAGE, 

LED/LIGHT, and CURRENT/MAGNETIC FIELD sensors. 

 

 

 

 

 

 

Serial Connections

Connect up to 2 RS-232 serial controlled devices using the  
included DB9 to RJ-45 adapters. The gSC2 serial outputs are not 
compatible with RS-485 serial devices. If your project requires  
RS-485 connections you will need to use a gSC10 controller.  
  
 
 

RS-232 wiring pin-outs are as follows: 

RS-232 Connections

The table shows the 568A and 568B color codes and the  
function of each conductor of the RS-232 ports. Please refer to 
the ELAN Integration Note for the specific device to determine 
the proper RJ45 to DB9 adaptor to use.

2

DC Power

Connection

Serial 

Connections

2 bi-directional RS-232 Ports 

Sense Input

Connections

2 ELAN Sensor
input Ports 

IR Outputs

4 discrete IR channels.
Compatible with Xantech 
single and dual emitters.

USB Modem Connections

USB - See Integration Notes for compatible equipment

Ethernet Connection

Ethernet - 10/100 Mbps
PoE IEEE 802.3at Type 2
48 VDC, 600 mA 

Relay 

Connections

2 Normally Open Relays
12VDC 24VAC @ 1 
AMP Compatibility

WIFI Antenna

802.11 b/g/n 

Reset

Reset's the 
unit's IP  address 
to factory default 
(DHCP). 

Press and hold 
for programming 
reset.

Factory use

ONLY

E L A N  

                                                       

HC4/HC8 

INSTALLATION MANUAL

 

©

 

ELAN 2010 

|

 All rights reserved

 

Page 20 

 

RS-232 Connections (Continued) 

The table below shows the 568A and 568B color codes and the function of each conductor 
of the RS-232 ports.  Note that Comm ports one and two use pins two and three for 

hardware handshaking.  Some 3

rd

 party devices require these connections. 

See the Integration Notes for the devices you are connecting to determine which Comm 
Ports and DB9 to RJ45 adapters are appropriate 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS-232 Port Pin # 

568A Color Code 

568B Color Code 

 

 

Function  

(Ports 3 +) 

White/Green 

White/Orange 

N/C 

N/C 

Green 

Orange 

DCD 

N/C 

White/Orange 

White/Green 

DTR 

RTS 

Blue 

Blue 

GND 

GND 

White/Blue 

White/Blue 

RXD 

RXD 

Orange 

Green 

TXD 

TXD 

White/Brown 

White/Brown 

CTS 

CTS 

Brown 

Brown 

RTS 

RTS 

Function 

 

 

12

13

Software upgrade

Prior to configuring the product, upgrade the gSC2 software to 
the latest version of g! Core Module. Core Module can be found 
on the ELAN dealer website. The gSC2 is not compatible with g! 
Core Module releases prior to g!7.0.

Connecting to the gSC2 on your network

The gSC2 is set from the factory for DHCP networking, which 
means it receives its IP address from the network router.  
Use g!Tools to find the address and connect to the gSC2.

 

 

TEST

The TEST connection is for factory and repair access only.  
Do not plug anything into the TEST port. Plugging anything into 
the TEST port will void the warranty and release the magic smoke.

Power Connection

Once all other connections have been completed, connect the 
supplied 12VDC power supply and engage the power switch on 
the front of the gSC2.

10

11

 

RESET Switch

When pressed momentarily the RESET switch will clear the static IP setup and return the gSC2 to  
DHCP as well as reset the WiFi configuration to factory default. When pressed and 
held for more than 15 seconds the programming of the current version will be reset to  
default. Pressing RESET while applying power will reset the software to the factory version. 

WARNING! THIS CANNOT BE UNDONE!!!

9

 

 

 

USB connection

Some accessories may be connected to the gSC2’s USB 

 

connector. Refer to the ELAN Integration Note for the device prior 
to connection. 
 

Ethernet Connection

Connect the Ethernet connection to an available 10/100 Mbps  
port on the network. This is the preferred connection. 
The gSC2 may be powered over Ethernet (PoE). PoE connection 
must meet IEEE 802.3at Type 2 requirements of up to 25W 
(@50VDC 600mA max).

WiFi Antenna

The gSC2 includes a WiFi radio for installations where 

 

a hardwired Ethernet connection is not available. This flexibility  
allows the gSC2 to be used as both an primary 

 

controller and to act as an extender when necessary. Ethernet  
connection is preferred, and should always be used when 
available. The WiFi radio should be used sparingly and only in  
Extender Mode.

 

The antenna connector is a standard R SMA type  

connector. Use only antennas provided with the equipment 
or as listed on page 2 of this document. Configuring the WiFi  
radio may only be accomplished while the gSC2 is connected to  
an Ethernet connection and is covered in the g! Configurator  
reference guide.

6

7

8

 

IR Output Connections

Four discrete IR outputs are supplied to control third party devices. 
The outputs may be configured in g! programming to utilize a  
carrier or not. Each output is compatible with Xantech single and 
dual emitters.

5

DC Power

Connection

Serial 

Connections

2 bi-directional RS-232 Ports 

Sense Input

Connections

2 ELAN Sensor
input Ports 

IR Outputs

4 discrete IR channels.
Compatible with Xantech 
single and dual emitters.

USB Modem Connections

USB - See Integration Notes for compatible equipment

Ethernet Connection

Ethernet - 10/100 Mbps
PoE IEEE 802.3at Type 2
48 VDC, 600 mA 

Relay 

Connections

2 Normally Open Relays
12VDC 24VAC @ 1 
AMP Compatibility

WIFI Antenna

802.11 b/g/n 

Reset

Reset's the 
unit's IP  address 
to factory default 
(DHCP). 

Press and hold 
for programming 
reset.

Factory use

ONLY

Use only with the cart, stand, tripod, bracket or table specified by the manufacturer or sold with the apparatus. 
When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

Отзывы: