- 14 -
Cod. 1910000000260 - nv00
Return to normal mode:
- Automatically: Room temperature increases again for more than
1°C in less than ½ hour
-
Manually: Press the OK button, or modify the set-point on the ther
-
mostatic head or the central unit.
Then the thermostatic head returns to previous setting temperature.
Special cases:
-
This function doesn't work if Thermostatic head is in OFF / Anti
-
freeze Mode
In the set-up1 menu select the 5th LED
5th LED is red FIX if OPEN WINDOW is OFF
5th LED is green FIX if OPEN WINDOW is ON
Switch from OFF to ON by moving left and right.
Push OK to go back to SETUP I selection menu.
2.7 Exit of the setup1 menu
To leave SetUp1 menu 3 possibilities are available:
•
Push OK to go back to MAIN menu
•
Push OK for more than 10s to make a FACTORY RESET
•
My Head can automatically leave SetUp1 menu in case of no user
action for 30 seconds.
2.8 Brightness
The user is allowed to modify all LEDs brightness.
In the set-up2 menu, go on the 1st LED.
By default, the brightness is set to 25%. Move left and right to de
-
crease/increase brightness value with 8% steps. Possible values [ 8%
; 100% ].
8%
16%
25%
33%
41%
50%
58%
66%
75%
83%
91%
100%
Push OK to validate and go back to SETUP2 selection menu.
2.9 Antigrip
In order to prevent valve clamping, this function can be used.
If the valve exercise function is activated, the head is moving at least 1
time every 20 days (0.5mm and come back to previous position).
By default, this function is ACTIVATED.
In the set-up2 menu, go on the 2nd LED
2nd LED is red FIX if ANTIGRIP is OFF
2nd LED is green FIX if ANTIGRIP is ON
Switch from OFF to ON by moving left and right
Push OK to go back to SETUP2 selection menu
2.10 By Pass
When all My Heads installed are closed, in order to prevent the “over
-
load” failure from the boiler, in some system the use of By Pass function
could be needed.
The bypass function is to configure the off position (0=fully closed, other
x% opened even in off position).
English