background image

Focus Ring

135˚ Swivel Lens

LABELLING

INSTRUCTIONS FOR 

SAFE USE

CorDEX Instruments Ltd. 1 Owens Rd, Middlesbrough, TS6 6HE, UK

TP2410 – Explosionproof Digital Camera

Ex d IIB+H2 T6 GbTamb -20°C to +50°C 

ATEX –TRAC13ATEX0046X 

IECEx :IECEx TRC 13.0016X 

Serial Number- XXXX-XX-XXXX 

Year of Construction- YYYY

Powered by – Refer to Manual

II 2 G

XXXX

DO NOT OPEN WHEN EXPLOSIVE ATMOSPHERE PRESENT

The conditions referenced in this section 

relate specifically to hazardous area 

applications and must be followed.

In accordance with clause 5.1 of EN 60079-1, 

the critical dimensions of the flamepaths are:

• 

Contact the manufacturer for information on 

the dimensions of the flameproof joint

• 

The apparatus must only be used in areas 

where there is low risk of impac

• 

Do not charge battery pack in the hazardous 

are

• 

The battery must be removed from the 

camera and charged in the CorDEX 

Instruments ToughPIX II charging bay part 

number CDX-2400-XXX. Using a different 

charging device will void the certification.

• 

The ToughPIX II 2410 Series digital camera 

incorporates a protected battery system 

with a non-replaceable fuse. This fuse is 

only to be replaced by CorDEX Instruments 

or a CorDEX Instruments Approved Repair 

Facility. Failure to do so will void the 

certification.

• 

Ensure that the ToughPIX II 2410 Series 

digital camera battery pack is secured 

using the plug provided. If the plug is lost, 

only replace with a plug of the correct size 

and type. If in doubt, contact your nearest 

CorDEX Instruments representative.

• 

The ToughPIX II 2410 Series digital camera 

is manufactured from aluminium alloy; and 

must contain less than 7% magnesium by 

weight and incorporates toughened glass 

windows. This should be taken into account 

when considering the end use application.

• 

TheToughPIX II 2410 Series digital camera 

cannot be maintained in the field andmust 

be returned to the manufacturer should 

repair or maintenance be required.

• 

USB communications with the ToughPIX II 

2410 Series digital camera must only occur 

within the non-hazardous area

• 

When replacing the battery pack, the screw 

must be re-tightened to a torque of 1.5-4Nm 

and the cover cap replaced.

• 

Only CorDEX battery pack CDX2400-011 shall 

be use

Flamepath

Maximum 

Gap (mm)

Minimum L 

(mm)

Rearcarriage/

front carriage

0.04

6.5

Flash 

Window/

frontcarriage

0.1

13.8

LCDWindow/

frontcarriage

0.1

13.8

Lens window/

frontcarriage

0.1

13.8

Operatingrod/

rear and

0.1

10.5

RUGGED 

AUTHORITY

ToughPIX II

 – Explosion Proof Digital Camera

5

Отзывы: